48
13 Supplement
VEGAPULS C 22 • SDI-12
58345-EN-200806
•
Distance
– +dd.ddd (m)
– +dd.ddd (ft)
– +ddddd (mm)
– +ddd.dd (in)
•
Electronics temperature
– ttt.t (°C, °F, K)
•
Measurement reliability
– rrr (dB)
•
Device status
– eee (Errror code)
Example
Address = 0, Stage = 29,272m, Distance = 0,728m, Temperature = 25,4°C, reliability = 14dB, De-
vice Status = Good
Response : 0+29.272+0.728+25.4+14+0<CR><LF>
Address = 4, Stage = 14,887m, Distance = 0,113m, Temperature = 22,7°C, reliability = 14dB, De-
vice Status = M507 (Error in the device setting)
Response : 4+14.887+0.113+22.7+14+507<CR><LF>
13.4 Extended Commands
Command
Response
Description
aXRPOM!
a<value1><value2><CR><LF>
Read Power Operation Mode
aXWPOM<value1>!
a<value1><value2><CR><LF>
Write Power Operation Mode
aXRDU!
a<value1><CR><LF>
Read distance unit
aXWDU<value1>!
a<value1><value2><CR><LF>
Write distance unit
aXRTU!
a<value1><CR><LF>
Read temperature unit
aXWTU<value1>!
a<value1><CR><LF>
Write temperature unit
aXRSR!
a<value1><value2><CR><LF>
Read stage reference
aXWSR<value1>!
a<value1><value2><CR><LF>
Write stage reference
aXRAPUR!
a<value1><value2><CR><LF>
Read access protection unlock result
aXRPS!
a<value1><value2><value3><val
ue4><CR><LF>
Read parametrization state
aXRAPAM!
a<value1><CR><LF>
Read access protection active mode
aXWAPPUL<value1>! a<value1><CR><LF>
Write access protection parametrization lock
aXWAPPL<value1>!
a<value1><CR><LF>
Write access protection parametrization unlock
aXWAPEC<value1>!
a<value1><CR><LF>
Write access protection unlock with emergency
code