I
n systems with potential equalisation
,
connect the cable screen
directly to ground potential at the power supply unit
,
in the connection
box and at the sensor
.
T
he screen in the sensor must be connected
directly to the internal ground terminal
.
T
he ground terminal outside on
the housing must be connected to the potential equalisation
(
low
impedance
).
I
n systems without potential equalisation
,
connect the cable screen
directly to ground potential at the power supply unit and at the sensor
.
I
n the connection box or
T
-
distributor
,
the screen of the short stub to
the sensor must not be connected to ground potential or to another
cable screen
.
T
he cable screens to the power supply unit and to the
next distributor must be connected to each other and also connected
to ground potential via a ceramic capacitor
(
e
.
g
.
1
n
F
,
1500
V
).
T
he low
frequency potential equalisation currents are thus suppressed
,
but the
protective e
ff
ect against high frequency interference signals remains
.
T
he total capacitance of the cable and of all capacitors must not exceed
10
n
F
in
E
x applications
.
T
ake note of the corresponding installation regulations for
E
x
applications
.
I
n particular
,
make sure that no potential equalisation
currents
fl
ow over the cable screen
.
I
n case of grounding on both sides
this can be achieved by the use of a capacitor or a separate potential
equalisation
.
5
.
2
C
onnection procedure
P
roceed as follows
:
1
U
nscrew the housing cover
2
I
f an indicating and adjustment module is installed
,
remove it by
turning it slightly to the left
.
3
L
oosen compression nut of the cable entry
4
R
emove approx
.
10
cm
(
4
in
)
of the cable mantle
,
strip approx
.
1
cm
(
0
.
4
in
)
insulation from the ends of the individual wires
5
I
nsert the cable through the cable gland into the sensor
6
L
ift the opening levers of the terminals with a screwdriver
(
see
following illustration
)
C
able screening and
grounding
16
VEGACAL
62
•
P
ro
fi
bus
PA
5
C
onnect to power supply
30025
-
EN
-
090603
Содержание VEGACAL 62
Страница 1: ...Operating Instructions VEGACAL 62 Pro bus PA Document ID 30025 Capacitive...
Страница 14: ...Fig 5 In owing medium 14 VEGACAL 62 Pro bus PA 4 Mounting 30025 EN 090603...
Страница 57: ...VEGACAL 62 Pro bus PA 57 10 Supplement 30025 EN 090603...
Страница 58: ...58 VEGACAL 62 Pro bus PA 10 Supplement 30025 EN 090603...
Страница 59: ...VEGACAL 62 Pro bus PA 59 10 Supplement 30025 EN 090603...