VEGA SI-13/User Manual
25
Revision 08 – 04 May 2018
4 bytes
Reserve
4 bytes
Reserve
3.
Data packet from an external device, received via RS-232 or RS-485 interface
Size in bytes
Field description
1 byte
Packet type, this packet = 3
2 bytes
Total data size received via interface
1 byte
Data size in this packet
1 byte
Packet ordinal number
1 byte
Total quantity of packets
Array
Data
The LoRa data transfer technology limits the maximum packet size, depending on the
speed of packet transmission. If the readings log cannot be sent in one packet, it is divided into
several packets, which are sent in series until the entire requested log is sent. Records in the log
packet are arranged from the newest to the oldest.
4.
Packet with current readings from connected meter Merkuriy 206, sent regularly or
on request
Size in bytes
Field description
1 byte
Packet type, this packet = 4
1 byte
Meter address
4 bytes
Result (1 – success, 0 – fail)
4 bytes
Reading rate 1
4 bytes
Reading rate 2
4 bytes
Reading rate 3
4 bytes
Reading rate 4
5.
Packet with the confirmation of the execution of the command
Size in bytes
Описание поля
1 byte
Packet type, this packet = 5
1 bytes
Command code which must be confirm
1 byte
Result of the execution (1 – success, 0 - fail)