Note: Frame Size Limitations
Layer 1 framed mode - Frame size configuration is not available.
Layer 1 unframed mode - Traffic profile is constant at 100% bandwidth.
7.1.1.3 Error Injection
Error injection can only be performed during testing. The error type and injection rate are configured in the Error Injection tab.
Error type:
Select from Bit, CRC, IP Checksum (layer 3 only).
Injection Flow:
Determines how the selected errors will be injected.
Select a single error injection, a specific count, or error rate.
Rate and Count:
Configures the error rate and error count via the numeric pop-up keypad
Once the test is running, error injection is enabled by selecting the “Error Injection ” icon from the action pull down menu at the top
of the screen. Press the “error inject” button to injecting error at the predetermined settings.
BERT - Error Injection Setup
BERT - Error Injection Action menu