7.0 Advanced Mode
Advanced Mode
features advanced troubleshooting tests beyond basic signal level measurements. Further investigation may be
required when the OPM test mode indicates good signal level and TCSync is good but network is generating alarm or errors.
Advanced Results
provides a summary screen of network status and reports system errors/alarms status.
PLOAM
captures and decodes PLOAM messages exchanged between the Optical Line Terminal (OLT) and ONT.
Active ONU
lists all active ONUs currently on the network as determined by the OLT.
Starting/stopping/restarting measurements from
starts/stops/resets items in Advanced Mode, namely the power
level graphs. Start/stop from Advanced Setup relates to error/alarms on this page. If the ONU is restarted, the power measurement
will continue recording the signal levels. The decoded fields will be reset when the ONU is reconnected. Decoded messages
continue to persist until the new sync is achieved, when they get updated.
Pressing restart at any time clears the results, filling in the downstream decode after receiving the first
PON-ID downstream message. The upstream decode will be filled in when the ONU initializes.