XGS-PON OPM Setup menu
3. Inspect and clean the FX120 test ports. Inspect and clean the fiber patch cord from the OLT and insert it into the FX120 OLT test port.
Warning:
Never look directly into the beam of an active optical source as this may result in harmful
eye damage from radiation exposure
4. If 1490/1577nm light is detected, the 1490/1577nm
Status
will display
OK.
Verify that the measured 1490/1577nm signal level is green (see
). Confirm TC-Sync DS displays
OK UL/DL
. Consult VeEX technical support if you are not able to achieve TC-Sync.
5. All DS LEDs should turn from red to Green. If any LED remains red, clean and inspect the connectors again as specified in Step 4.
6. Inspect and clean the patch cord connectors that will connect FX120 to ONU/ONT and the ONU/ONT test port.
7. Connect the FX120 to the ONU/ONT test port. If 1310/1270nm light is detected, the Status will display
OK.
Verify that the measured 1310/1270nm
signal level is green (see
Signal and Synchronization Status
).
8. Confirm TC-Sync DS displays
OK UL/DL
. Consult VeEX technical support if you are not able to achieve TC-Sync.
9. All US LEDs should turn from red to green. If any LED remains red, clean the ONU connections again as outlined in Step 6.
Thresholds Adhering to the Current GPON Standard
s
FX120_User_Manual_RevA02
Page 17 of 32