background image

Table of Contents

iii

Introduction

Contractor Certification Requirements ..............................................................................1
Related Documents  ..........................................................................................................1
Safety Precautions ............................................................................................................1
TLS4/8601 Kits  .................................................................................................................2

Component Identification

..........................................................................................4

Component Replacement Procedures

Removing Display/CPU Assembly ....................................................................................8
Removing The SD Card ....................................................................................................8
Replacing The Features iButton  .......................................................................................9
Replacing the Backup Battery  ..........................................................................................9
Replacing the USIOM Board  ............................................................................................9

Software Maintenance and Upgrades

Activate/Revert Screen (Menu>Software Maintenance>Activate/Revert) ......................13

Notes on Reverting to a Previous Software Version ..............................................14

DB Backup (Menu>Software Maintenance>DB Backup) ................................................15

Example Database Backup Procedure...................................................................15

DB Restore (Menu>Software Maintenance>DB Restore) ..............................................16
Download (Menu>Software Maintenance>Download) ....................................................17

Example Software Download Procedure................................................................18

System Snapshot (Menu>Software Maintenance>System Snapshot)  ...........................19

Example System Snapshot Procedure...................................................................19

Upgrade Features (Menu>Software Maintenance>Upgrade Features) ..........................20

Figures

Figure 1.

TLS4/8601 Series Console - Dimensions

...............................................4

Figure 2.

Component Locations (Front Cover Removed)

......................................5

Figure 3.

Component Locations Underside Of Display/CPU Board Ass’y.

............6

Figure 4.

Component Locations USIOM Board 

....................................................7

Figure 5.

Inserting SD Card In Its CPU board Enclosure

.......................................9

Figure 6.

Remove all plugs attached to USIOM board

........................................10

Figure 7.

Remove Two T15 Screws Securing Comm Plate

.................................11

Figure 8.

Remove Two Corner T10 Screws From Power Supply Board

.............11

Figure 9.

Remove Lower Left Corner USIOM Board T15 Screw

.........................11

Figure 10.

Remove Two T15 Screws Securing I.S. Cover

....................................12

Figure 11.

USIOM Board Snap-On Retaining Post

................................................12

Figure 12.

Software Maintenance Screen

..............................................................13

Tables

Table 1. 

Miscellaneous Upgrade/Replacement Kits ................................................2

Table 2. 

Activate/Revert Screen Field Descriptions ..............................................14

Table 3. 

DB Backup Screen Field Descriptions  ....................................................15

Table 4. 

DB Restore Screen Field Descriptions ....................................................16

Table 5. 

Download Screen Field Descriptions  ......................................................17

Table 6. 

System Snapshot Screen Field Descriptions ..........................................19

Table 7. 

Upgrade Features Screen Field Descriptions .........................................20

Содержание TLS4/8601 Series

Страница 1: ...Manual No 577014 043 Revision C Software Hardware Upgrade Replacement Manual TLS4 8601 Series Consoles...

Страница 2: ...and Conditions VEEDER ROOT S PREFERRED CARRIER 1 Contact Veeder Root Customer Service at 800 873 3313 with the specific part numbers and quantities that were missing or received damaged 2 Fax signed...

Страница 3: ...tware Maintenance Upgrade Features 20 Figures Figure 1 TLS4 8601 Series Console Dimensions 4 Figure 2 Component Locations Front Cover Removed 5 Figure 3 Component Locations Underside Of Display CPU Bo...

Страница 4: ...ed to perform installation checkout startup programming system tests troubleshooting service techniques and operations training on the designated system Wireless 2 Tall Tank Related Documents 577014 0...

Страница 5: ...safety Table 1 Miscellaneous Upgrade Replacement Kits Part No Kit 330020 742 Upgrade DL4 To TLS4 EDIM With Touch Screen 333530 002 Feature Upgrade TLS4 TLS4B TLS4c TLS4i TLS S1 DL4 330020 744 Operati...

Страница 6: ...it AC TLS4B TLS4c TLS S1 DL 330020 769 iButton Replacement Kit TLS4 TLS4B TLS4c TLS4i TLS S1 DL4 DL 330020 754 USB Back up Thumb Drive TLS4 TLS4B TLS4c TLS4i TLS S1 DL4 DL 330020 755 Replacement TLS4...

Страница 7: ...Serial number 3 Intrinsically safe wiring conduit knockout 1 top 1 bottom 4 Optional touch screen display 5 Status LEDs 6 T15 screws secure cover 2 places 7 Communication ports standard Serial ports 1...

Страница 8: ...Lithium battery battery backup 6 RS232 485 selection jumpers SERIAL 1 P1 and SERIAL 2 P2 factory set to RS232 position 7 T20 screw secures Display CPU assembly 8 Optional 6 device intrinsically safe...

Страница 9: ...ure 3 1 J36 Mode Jumper shown in Operating Mode Position 2 SD Card 3 Software Features iButton 4 Display ribbon cable connector Consoles with GUI display only 5 Ack switch cable connector J40 Consoles...

Страница 10: ...NG TERMINALS WARNING SUBSTITUTION OF COMPONENTS MAY IMPAIR INTRINSIC SAFETY INTRINSICALLY SAFE CIRCUITS ARE ALSO RATED AS CLASS 2 CIRCUITS TERMINALS ARE FOR CONNECTION TO I S TANK PROBES AND SENSORS U...

Страница 11: ...cables 4 Remove the T15 8 x 0 3125 screw Item 4 in Figure 2 and the T20 8 x 0 875 screw Item 7 in Figure 2 securing the Display CPU assembly to the console and set them aside Slide the Display CPU as...

Страница 12: ...der Replacing the Backup Battery 1 Remove the front cover of the TLS4 following step 1 and 2 of the Display CPU Assembly removal instructions on page 8 2 Locate the backup battery beneath the display...

Страница 13: ...of the USIOM board out enough to release the USIOM board from the snap on retaining post between the two I S sockets see Figure 11 9 With the USIOM board now free from the retaining post swing the rig...

Страница 14: ...TING 5A N G L 0 C Ta 50 C FOR SUPPLY CONNECTION USE WIRES RATED FOR AT LEAST 90 C RELAY 2 RELAY 1 F1 F2 5A SLO BLO F4 5A F7 EB 1 2 3 4 5 6 7 8 9 10 11 12 INTRINSICALLY SAFE WIRING TERMINALS WARNING SU...

Страница 15: ...CONNECTION USE WIRES RATED FOR AT LEAST 90 C RELAY 2 RELAY 1 RTN 12V PWR STAT PWR INT F1 F2 5A SLO BLO F4 5A SLO BLO F6 0 75A SLO BLO F7 EB25918024 2 3 4 5 6 7 8 9 10 11 12 INTRINSICALLY SAFE WIRING T...

Страница 16: ...e Maintenance Activate Revert This screen lets you activate newly installed software or revert to a previously stored version of software During the activation process several dialog boxes will be dis...

Страница 17: ...ilable will display if a version of software has not been stored Current Operation Status of the console Idle no software is being installed or reverted or Activating a software install is in progress...

Страница 18: ...creen Field Descriptions Field Description Current Version Current version of software x xx xxx x installed in the console Available Version Not applicable to a backup Current Operation Status of the...

Страница 19: ...location Table 4 DB Restore Screen Field Descriptions Field Description Current Version Current version of software x xx xxx x installed in the console Available Version Version of software that can...

Страница 20: ...load Screen Field Descriptions Field Description Current Version Current version of software x xx xxx x installed in the console Available Version Version of software that can be accessed on the USB d...

Страница 21: ...rrent version and Available downloaded version are displayed screen shot 7 Touch the box beside the message Click to acknowledge the system will be stopped 8 Touch the Activate button to overwrite the...

Страница 22: ...bdrive Notice the Version field displays information about the thumbdrive 4 Touch the Take Snapshot button to begin the procedure 5 After successful completion of the snapshot approximately 3 minutes...

Страница 23: ...ew feature s will be required Table 7 Upgrade Features Screen Field Descriptions Field Description Feature box List features which are available to be activated Multiple features may be activated conc...

Страница 24: ...For technical support sales or other assistance please visit www veeder com...