TLS Magnetostrictive Probes International Installation Guide
Probe and Riser Installation Criteria
13
Probe and Riser Installation Criteria
Mag probe installations require a 2-inch or 3-inch (51 or 76mm) riser, regardless of tank entry size. Entry sizes of 1
inch, or entries larger than 3 inches must be with the suitable fittings.
The canister of the probe must be completely contained within the riser. In all cases, the probe must rest on the
bottom of the tank (see Figure 13). Risers, when fitted, should be a minimum of 100mm above the probe canister.
Figure 13. Typical Probe Installations In Riser Pipe
51mm Ri
s
er
Ri
s
er m
us
t
b
e
51mm ID
a
nd free
of
bu
rr
s
.
76mm Ri
s
er
76mm Entry
51mm Entry
Boot
031-10
View 1
View 2
I
n
stalli
n
g with a
76
mm
o
r
102
mm
Rise
r
Pipe
I
n
stalli
n
g with a
51
mm
Rise
r
Pipe
Note: The
r
ise
r
pipe cap fo
rm
s a suitable
p
r
ocess co
nn
ectio
n
at the bou
n
da
r
y wall.