TLS Magnetostrictive Probes International Installation Guide
Procedures for Installing Mag Probes
6
Figure 2. Procedures For Installing Mag Probes Using Wireless Connections
Mag Probe
Installation Complete
Install either a sleeve or an
adapter as shown on Figure 17,
then install the Mag Probe in a
riser pipe according to the
instructions on Figure 13 of this
manual.
Install a single channel surge
protector, part number 848100-
001, according to Figure 25 of
this manual.
Install the Mag Probe with a
process connection according to
the instructions on Figures 14 and
24 of this manual.
Riser Pipe
Process Connection
Mag Probe
Installation Complete
Procedure for installing Mag
Probes into storage tanks
using a riser pipe.
NOTE: Use a riser pipe in
locations that do not require
bonding between the Mag
Probe and the tank structure.
Procedure for installing Mag
Probes into storage tanks
using a tube gland.
NOTE: Use a tube gland in
locations where it is
mandatory that the Mag Probe
be equipotentially bonded to
the tank structure.