background image

Notice

Veeder-Root makes no warranty of any kind with regard to this publication, including, but not limited to, the implied warranties of
merchantability and fitness for a particular purpose.

Veeder-Root shall not be liable for errors contained herein or for incidental or consequential damages
in connection with the furnishing, performance, or use of this publication.

Veeder-Root reserves the right to change system options or features, or the information contained in this publication.

This publication contains proprietary information which is protected by copyright. All rights reserved. No part of this publication
may be photocopied, modified or translated to another language without the prior written consent of Veeder-Root.

Contact TLS Systems Technical Support for additional troubleshooting information at 800-323-1799.

DAMAGE CLAIMS / LOST EQUIPMENT

Thoroughly  examine  all  components  and  units  as  soon  as they are  received.  If any  cartons  are damaged  or  missing, write  a
complete and detailed description of the damage or shortage on the face of the freight bill. The carrier's agent must verify the
inspection and sign the description. Refuse only the damaged product, not the entire shipment.
Veeder-Root must be notified of any damages and/or shortages within 30 days of receipt of the shipment, as stated in our Terms
and Conditions. 

VEEDER-ROOT’S PREFERRED CARRIER

1. Contact Veeder-Root Customer Service at 800-873-3313 with the specific part numbers and quantities that were missing

or received damaged.

2.

Fax signed Bill of Lading (BOL) to Veeder-Root Customer Service at 800-234-5350.

3. Veeder-Root will file the claim with the carrier and replace the damaged/missing product at no charge to the customer.

Customer Service will work with production facility to have the replacement product shipped as soon as possible.

CUSTOMER’S PREFERRED CARRIER

1. It is the customer’s responsibility to file a claim with their carrier.

2. Customer may submit a replacement purchase order. Customer is responsible for all charges and freight associated with

replacement order. Customer Service will work with production facility to have the replacement product shipped as soon as
possible.

3. If “lost” equipment is delivered at a later date and is not needed, Veeder-Root will allow a Return to Stock without a restocking

fee.

4. Veeder-Root will NOT be responsible for any compensation when a customer chooses their own carrier.

RETURN SHIPPING

For the parts return procedure, please follow the appropriate instructions in the "General Returned Goods Policy” pages in the

 

"Policies and Literature" section of the Veeder-Root 

North American Environmental Products

 price list. Veeder-Root will not

 

accept any return product without a Return Goods Authorization (RGA) number clearly printed on the outside of the package.

FOR INSTALLATIONS IN THE STATE OF CALIFORNIA

Please refer to the Vapor Recovery Certification Phase II EVR Executive Orders at the California Air Resources Board website

 

(

www.arb.ca.gov

) for the latest manual revisions pertaining to Executive Orders VR-202 (Assist Phase II EVR System Including

 

ISD System), VR-203 (Balance Phase II EVR System) 

or

 VR-204 (Balance Phase II EVR System Including ISD System).

 ©Veeder-Root 2023. All rights reserved

.

Содержание TLS-3 Series

Страница 1: ...Manual No 577013 797 Revision P Installation Guide Vapor Pressure Sensor TLS 450PLUS TLS 3XX Consoles...

Страница 2: ...signed Bill of Lading BOL to Veeder Root Customer Service at 800 234 5350 3 Veeder Root will file the claim with the carrier and replace the damaged missing product at no charge to the customer Custom...

Страница 3: ...stall in Horizontal Access Fitting or Vapor Return Line ISD Installation with Air Flow Meter Below Shear Valve 11 Figure 5 Example VPS Installation Below Vertical Access Fitting or Vapor Return Line I...

Страница 4: ...ded safety practices identified by OSHA and your employer Review and comply with all the safety warnings in this an any related documents and any other Federal State or Local requirements Warranty Reg...

Страница 5: ...Install Setup Operation Manual TLS 350 For Sites With TLS 450PLUS Consoles 577014 073 TLS 450PLUS Site Prep and Installation Manual 577014 484 Veeder Root ISD For TLS 450PLUS Consoles Install Manual V...

Страница 6: ...dress practices not related to physical injury WARNING This product is to be installed and operated in the highly combustible environment of a gasoline dispenser where flammable liquids and explosive...

Страница 7: ...ified yellow Gas TFE plumbing tape Intrinsically safe devices must be installed in accordance with Article 504 of the National Electrical Code ANSI NFPA 70 for installation in the United States or Sec...

Страница 8: ...S bend 333006 001 10 1 Tube copper 1 4 OD x 8 length 333018 001 11 1 Ball valve 3 way 1 4 576008 649 12 1 Hub conduit liquid tight 1 2 zinc 576010 715 13 3 Conduit clamp 2 steel std duty 514100 478 1...

Страница 9: ...m and necessary bolts nuts and washers from the included Universal Sensor Mounting kit Wrap the rubber shim item 10 in Table 1 around the sensor before inserting it into the clamp The VPS sensor must...

Страница 10: ...VPS wiring with wire nuts see Figure 6 For Wireless installations skip Steps 11 13 The VPS sensor connects to a TLS RF transmitter not to field wiring from the TLS Console see manual 577013 964 for in...

Страница 11: ...enser 2 or 3 common main vapor return line Pressure Sensor Wrap rubber shim from kit around sensor before inserting in clamp Pressure sensing port Cable Vapor return line shear valve Cord grip Base of...

Страница 12: ...2 or 3 common main vapor return line Pressure Sensor Wrap rubber shim from kit around sensor before inserting in clamp Pressure sensing port Cable Vapor return line shear valve Cord grip Base of dispe...

Страница 13: ...Wrap rubber shim from kit around sensor before inserting in clamp Pressure sensing port Cable Vapor return line shear valve Cord grip Base of dispenser cabinet 797 9 eps Pitch to drain 1 4 vertical p...

Страница 14: ...sensor before inserting in clamp Pressure sensing port Pitch to drain 1 4 vertical per 12 horizontal 12 4 11 2 2 2 2 3 2 1 10 OR Seal off customer supplied Conduit to TLS Console Cable Cord grip Flow...

Страница 15: ...ng port 3 1 10 Seal off customer supplied Conduit to TLS Console Cable Cable Cord grip Flow Meter and Pressure Sensor wiring can share the same conduit to console Observe polarity Required Y fitting f...

Страница 16: ...wn in A bend pak along long length 3 As shown in B firmly squeeze the RED SIDE of the resin forcing it through the center seal and into BLACK SIDE 4 Mix thoroughly to a uniform color by squeezing cont...

Страница 17: ...4 Figure 8 Direct Wired VPS Connects to Available TLS 450PLUS USM Module Position Figure 9 Direct Wired VPS Connects to Available TLS 3XX Smart Sensor Interface Module Position For wireless configurat...

Страница 18: ...e item 2 in Table 2 such that the VPS cable outlet is facing up and the pressure sensing port tube in the base of the sensor is facing down The symbol on the panel should be facing upward Use the four...

Страница 19: ...of the tube up and estimate the length needed to loop from the bottom of the drying tube over to the vent port off center of the VPS Cut the Tygon tubing at the estimated length approximately a foot...

Страница 20: ...VPS Installation Vapor Vent Stack Installation Wired VPS 1717 Figure 10 Locating Direct Wired VPS Sensor Enclosure on Vapor Vent Stack...

Страница 21: ...VPS Installation Vapor Vent Stack Installation Wired VPS 18 Figure 11 Direct Wired VPS Sensor Installed in Vapor Vent Stack Enclosure...

Страница 22: ......

Отзывы: