background image

1. 

DISPLAY

: 5 digit LCD 0.48" (12.2 mm) high digits

RFMP00R

: Reflective LCD with full viewing angle

RFMP00

: Transmissive LCD with selectable red or green LED backlight,  

viewing angle optimized. Display color change capability with output state 

when using an output module.

2. 

POWER

: Input voltage range is +9 to +28 VDC with short circuit and input 

polarity protection. Must use an VR model RFMPS or an NEC Class 2 or 

Limited Power Source (LPS) rated power supply.

3. 

INPUT RANGES

: Jumper Selectable

0 to 10 V, 0(4) to 20 mA, 0 to 50 mA

4. 

SENSOR INPUTS:

5. 

OVERRANGE RATINGS, PROTECTION & INDICATION:

9 to 28 VDC power circuit is not isolated from the signal circuit.

Input Overrange Indication

:  “

OLOL

”.

Input Underrange Indication

:  “

ULUL

”.

Display Overrange/Underrange Indication

: “

.....

”/“-

.....

” 

6. 

RESPONSE TIME

:

Display

: 500 msec min.

Output

: 800 msec max (with input filter setting of 0)

7. 

NORMAL MODE REJECTION

: 60 dB 50/60 Hz

8. 

USER INPUT (USR)

: Programmable input. Connect USR terminal to USR 

COMM to activate function. Internal 10K

 pull-up resistor to +9 to 28 VDC.

Threshold Levels

: V

IL

 = 0.7 V max; V

IH

 = 2.4 V min; V

MAX

 = 28 VDC 

Response Time

: 5 msec typ.; 50 msec debounce (activation and release)

9. 

CONNECTIONS

: Wire clamping screw terminals

Wire Strip Length

: 0.3" (7.5 mm)

Wire Gage

: 30-14 AWG copper wire

Torque

: 5 inch-lbs (0.565 N-m) max.

10. 

MEMORY

: Nonvolatile E

2

PROM memory retains all programming 

parameters and max/min values when power is removed.

11

ENVIRONMENTAL CONDITIONS

:

Operating Temperature Range for RFMP00R

: -35 to 75 °C

Operating Temperature Range for RFMP00 depends on display color 

and intensity level as per below

:

INTENSITY LEVEL

TEMPERATURE

Red Display

1 & 2

-35 to 75 °C

3

-35 to 70 °C

4

-35 to 60 °C

5

-35 to 50 °C

Green Display

1 & 2

-35 to 75 °C

3

-35 to 65 °C

4

-35 to 50 °C

5

-35 to 35 °C

Storage Temperature

: -35 to 85 °C

Operating and Storage Humidity

: 0 to 85% max. relative humidity (non-

condensing)

Vibration to IEC 68-2-6

: Operational 5-500 Hz, 5 g

Shock to IEC 68-2-27

: Operational 30 g

Altitude

: Up to 2000 meters

12.

 CERTIFICATIONS AND COMPLIANCES

:

 CE Approved

EN 61326-1 Immunity to Industrial Locations

Emission EN 55011 Class A

IEC/EN 61010-1

UL Recognized Component: File #E179259

UL Listed: File #E137808

Type 4X Enclosure rating (Face only)

IP65 Enclosure rating (Face only)

IP20 Enclosure rating (Rear of unit)

Refer to EMC Installation Guidelines section of the bulletin for additional 

information.

13. 

CONSTRUCTION

: This unit is rated for NEMA 4X/IP65 requirements for 

outdoor use. Installation Category I, Pollution Degree 2. High impact plastic 

case with clear viewing window. Panel gasket and mounting clip included.

14. 

WEIGHT

: 3.2 oz (100 g)

2

G

eneral

 M

eter

 S

pecificationS

o

rderinG

 i

nforMation

MODEL  

NO.

DISPLAY COLOR

INPUT CURRENT 

@ 9 VDC WITH  

RFMRLOO

RFMPOOR

---

10 mA

40 mA

RFMPOO

Red (max intensity)

85 mA

115 mA

RFMPOO

Green (max intensity)

95 mA

125 mA

INPUT CURRENT 

@ 9 VDC WITHOUT 

RFMRLOO

ACCURACY 

@23 °C, less 

than 85% RH

INPUT 

RANGE

INPUT 

IMPEDANCE

MAX INPUT 

SIGNAL

RESOLUTION

TEMP. 

COEFFICIENT

20 / 50 mA 0.1% of span

10 

150 mA

1 µA

70 ppm / °C

10 VDC 0.1% of span 538 K

30 V

1 mV

70 ppm / °C

TYPE

MODEL NO.

DESCRIPTION

PART NUMBER

FLEX MINI

FLEX MINI

Process Meter with Reflective Display

RFMP00R

Process Meter with Backlight Display

RFMP00

Optional Plug-in Cards

FLEX MINI

Single Relay Option Card

RFMRL00

FLEX MINI

Dual Sinking Open Collector Output Card

RFMSK00

FLEX MINI

RS485 Serial Communications Card

RFMCOMM

RS232 Serial Communications Card

RFMCOMM2

FLEX MINI

USB Programming Card 

RFMCOMUSB

Accessories

FLEX MINI

+12 VDC Micro-Line Power Supply, 85 to 250 VAC source, 400 mA max out

RFMPS1

Содержание RFMP Series

Страница 1: ...FLEX MINI can be powered from an optional Veeder Root Micro Line Sensor Power Supply MLPS which attaches directly to the back of a FLEX MINI The MLPS is powered from 85 to 250 VAC and provides up to 4...

Страница 2: ...C Green Display 1 2 35 to 75 C 3 35 to 65 C 4 35 to 50 C 5 35 to 35 C Storage Temperature 35 to 85 C Operating and Storage Humidity 0 to 85 max relative humidity non condensing Vibration to IEC 68 2 6...

Страница 3: ...5 SERIAL COMMUNICATIONS CARD Type RS485 multi point balanced interface non isolated Baud Rate 300 to 38 4k Data Format 7 8 bits odd even or no parity Bus Address 0 to 99 max 32 meters per line Transmi...

Страница 4: ...thin an enclosure should be routed as far as possible from contactors control relays transformers and other noisy components 5 In extremely high EMI environments the use of external EMI suppression de...

Страница 5: ...UNREG 400mA 12V DC COMMON M3424B TERMINAL AC INPUT MLPS1 2 WIRE TRANSMITTER COMM INP _ MODEL INPUT POWER OUTPUT POWER 85 250 VAC 50 60Hz 14VA OPERATING TEMP 0 TO 60 C 12VDC UNREG 400mA 12V DC COMMON...

Страница 6: ...the SEL button with Pro NO displayed This will commit any stored parameter changes to memory and return the meter to the Display Mode If power loss occurs before returning to the Display Mode verify...

Страница 7: ...Values have to be derived from the actual input signal source or simulator the Apply APLY scaling style must be used KEy APLY 0 000 INP 1 INPUT VALUE FOR SCALING POINT 1 For Key in KEY style enter th...

Страница 8: ...ow FACTORY SERVICE OPERATIONS yES NO YES NO Enables the Maximum Display Capture capability Enables the Minimum Display Capture capability The RFMP uses stored calibration values to provide accurate vo...

Страница 9: ...acklight Unit Only 3 dSP dSP t SEL rSt ZErO UNItS COLOr CodE Display Intensity Level d LEV ScroL Display Scroll Enable PARAMETER MENU The yES selection allows the SEL button to toggle through the enab...

Страница 10: ...ced are affected by the hysteresis When the setpoint is a control output usually balanced hysteresis is used For alarm applications usually unbalanced hysteresis is used For unbalanced hysteresis mode...

Страница 11: ...s Refer to the RFMCOMUSB bulletin for details on the FLEX MINI USB programming and programming requirements PARAMETER MENU button or user input manual reset serial reset command or meter power cycle W...

Страница 12: ...tOF n rSt n rEn n ChC n Standby Operation Stb n Front Panel Reset Enable Front Panel Display Select Enable Display Update Time dSP t SEL rSt 3 dSP Display Intensity Level COLOr Units Indicator Select...

Отзывы: