A-1
Appendix A: EMR4 Setup - Programming Tips
For Typical Single or Dual-head Installations with One IB
Order
Activity
Comment
1
Time Delays (Setup, non C&C -
ref. Figure 29 on page 29)
Increase TIME DELAYS to get screen and backlight to stay on longer. For
example, set it to 630 seconds.
2
Printer Option (Setup, non C&C -
ref. Figure 17 on page 21)
Enable printer so it is available for use (default is standard slip printer
type).
3
Language and labels - defaults to
English, must select French
(C&C - ref. Figure 31 on page 32)
• Defaults to English, Gallons, Dollars.
• If French is selected, then all labels change to French.
• Note that for French the currency defaults are Euros, and the Euros
symbol will be on the ticket format.
4
Display Syntax (C&C - ref.
Figure 34 on page 35)
Defaults to tenths for volume. It is recommended that even if you want to
display whole unit volume, that you do all calibrations with the display set
to tenths of a unit volume, then change to display whole unit volume.
5
Temperature (If Temperature
Compensation is desired)
• Temperature Compensation by
Density or Coefficient? (C&C -
ref. Figure 40 on page 39)
• Temperature - default is
Fahrenheit, need to change for
Celcisus (C&C - ref. Figure 35
on page 36)
• Change Reference Temperaure
from default of 15°C or 60°F?
(C&C - ref. Figure 36 on
page 36)
• Temperature calibration
Temperature probe must be connected for temperature to be available.
• Necessary to select for Product Setup (defaults to Coefficient).
• Selection of temperature probe units of measurement
• Temperature probe’s calibration reference temperature units of
measurement must match Temperature probe units of measurements
• Use ice water bath as per manual, or a known temperature.
6
Meter ID (C&C Fuel Source
setup, ref. Figure 37 on page 37)
Text for Meter ID, e.g., the truck number.
7
Input Type and Meter Direction
(C&C Fuel Source setup, ref.
Figure 37 on page 37)
Defaults to Quadrature input type which is the pulse generator supplied
by V-R. In this setup you also change the meter’s direction if it is counting
backwards. Default is clockwise (CW).
8
Product Setup (Dscrip) (C&C -
ref. Figure 40 on page 39)
• 8 products available.
• Select Product Type first. this loads the proper Temperature
Compensation table/factor and assigns the default name to the product.
If necessary, you can change the Product Name in this same setup.