VEDUM Flow 500 Скачать руководство пользователя страница 5

5

Flow & Zone

5 kg

Samtliga mått är angivna i mm.

All dimensions are given in mm.

Note 1: c/c-mått för regel i vägg och borrhål till väggskena N.

spacing floor to joist in wall and drill holes for rail N.

Note 2: utgång avlopp i vägg max 550 mm över golv.

output drain in wall max 550 mm above the floor.

38

0

53

0

10

0

75

Grayed area=suitable area for wall socket

25

0

Fastsättning

Höjdjustering

Higher/ Lower

Tighten

Flow & Zone

UPPSÄTTNING AV SKÅP 

/Assembling of cabinets

G

en

er

el

l t

ol

er

an

lle

r d

å 

ej

 a

nn

an

 to

le

ra

ns

 a

ng

es

. S

am

tli

ga

 m

åt

t ä

r a

ng

iv

na

 i 

m

ill

im

et

er

.

D

en

na

 ri

tn

in

in

ne

lle

r p

ro

pr

ie

r i

nf

or

m

at

io

so

m

 ti

llh

ör

 V

ED

U

M

®

 o

ch

 få

r i

nt

he

lt 

el

le

r d

el

vi

s

re

pr

od

uc

er

as

 e

lle

r a

vs

ja

ut

an

 fö

re

en

de

 

sk

rif

tli

gt

 ti

lls

nd

. V

ed

um

 K

ök

 &

 B

ad

 A

20

18

Skala

Ritad

Generell Tolerans ±

Granskad

Godkänd

Datum

Vyplacering

Ritningsnummer

Revision

Benämning

1 : 2

emhi

-

Mark-00550

VÄGGSKENA HÅL-MARKERING

0,30

Sida

1 / 1

c/c

Skala

Ritad

Generell Tolerans ±

Granskad

Godkänd

Datum

Vyplacering

Ritningsnummer

Revision

Benämning

2 : 1

emhi

-

Mark-00545

TILLBEHÖRSPÅSE  VÄGGSKENA

+SAMMANBINDNINGSSKRUV

0,30

Sida

1 / 1

Skruva först i de yttersta ovala hålen, justera skenan och fixera sedan med 
de inre skruvarna. Bricka (Ø6x16x1 mm) används i de yttre ovala hålen.  

2 st

6 st

6 st

1. 

Montera väggskenan på angiven placering. Kontrollera väggmaterial 
och välj annan skruv om den bifogade ej passar. Bifogad skruv  
(Ø6x50 mm) är avsedd för att fästas i träregel eller betong. Borra hål 
i vägg enligt illustrationen nedan. Fyll de borrade hålen med silikon 
innan skruv dras.

2. 

Plocka ur lådorna ur underskåpet, för att förenkla upphängning  

 

och justering.

3. 

Häng upp skåpet på väggskenan. 

4. 

Kontrollera att skåpet är i våg, justera vid behov.

5. 

Dra åt skruvarna försiktigt så att beslagen spänner fast skåpen mot 
väggen (använd ej skruvdragare).

6. 

Vid tvättställspaket med två underskåp: Använd tving för att  
sammanfoga skåpen. Sammanbind sedan skåpen med bifogade  
skruvar (Ø4x28 mm).

7. 

Underskåp för tvättställ ska också skruvas i väggen med skruvregeln 
för ökad säkerhet. Även högskåp ska skruvas i nedre skruvregel för 
ökad säkerhet.

Verktyg

Tools

Ø6x16x1 mm

Ø6x50 mm

Ø6x50 mm

Art.nr. 508920

4 st

Ø4x28 mm

3

5

4

6

1

First screw in the outer oval hole, adjust and fix the rail with the next screw. 

Washer

 (Ø6x16x1 mm) are used in the outer oval holes.

1. 

Install the wall rails in the indicated position. Check wall material and 
choose a different type of screw if those included are not suitable.  
Included screws (Ø6x50 mm) are intended for fixing to wooden  
beams or concrete. Drill holes in the wall as the illustration below.  
Fill the drilled holes with silicone before securing the screws. 

2. 

Remove the drawers from the cabinet, to simplify hanging and  
adjustment. 

 

     

3. 

Hang the cabinet on the wall rail. 

4. 

Make sure that the cabinet is placed horizontal. Adjust if needed. 

5. 

Tighten the screws so that the fittings lock the cabinet towards the 
wall (do not use a electrical screw driver).

6. 

In case of washstand package with two cabinets: Use clamps to join 
the cabinets. Then connect the cabinets with the included screws  
(Ø4x28 mm).   

 

7. 

For increased safety, the vanity-unit shall also be mounted to the wall 
by the bolt with plugs and screws. This shall also be applied to the 
high 

cabinet. 

     

Содержание Flow 500

Страница 1: ...Monteringsanvisning Flow Zone Installation guide Flow Zone...

Страница 2: ...ST LLSPAKET FLOW Washstand packages Flow Zone 600 Zone 1200 Zone 1500 Zone 2000 Zone 1000 F rvaringssk p 600 Storage cabinet H gsk p High cabinet F rvaringssk p 1000 Storage cabinet TV TTST LLSPAKET Z...

Страница 3: ...806 Note 2 862 170 206 Note 2 732 Note 1 806 Note 2 857 902 842 842 Note 1 c c m tt f r regel i v gg och borrh l till v ggskena N Spacing floor to wall stud and drill holes for rail N Note 2 c c m tt...

Страница 4: ...es for rail AVLOPP I V GG Drain in wall 525 450 65 16 16 390 A Av vllo op pp p F FL LO OW W 6 60 00 0 1 1L L 520 570 A Av vllo op pp p F FL LO OW W 5 50 00 0 550 650 842 862 732 N No ot te e 1 1 170 2...

Страница 5: ...tera vid behov 5 Dra t skruvarna f rsiktigt s att beslagen sp nner fast sk pen mot v ggen anv nd ej skruvdragare 6 Vid tv ttst llspaket med tv undersk p Anv nd tving f r att sammanfoga sk pen Sammanbi...

Страница 6: ...it possible to adjust or disassemble the washstand if necessary 2 Place a thin string of wet room silicone along the edge press firmly on the washstand Immediately wipe out excess wet room silicone i...

Страница 7: ...ieranzahl Number o Gewicht in kg Weight in kg H he in mm Height in mm D mpfleistung erh hen schwere Stufe Increase damping power high level D mpfleistung beibehalten mittlere Stufe Maintain damping po...

Страница 8: ...n each side To adjust the drawer front sideways move the hooks back and simultaneously pull the drawer front sideways Adjustment range 1 5 mm Screw A is a locking screw tall drawers have 2 locking scr...