VEC-1120K/1130K/1140K/1180K Instruction
Manual
16
78L05
!
!
9. Install the 78L05 so its body is keyed to the silk-screen outline for IC
U2. Re-form U2’s leads as needed so it sits close to the board.
Solder.
Installation of Electrolytic Capacitors:
Electrolytic capacitors are
polarized
devices, and must be inserted with respect
to polarity. The style used in the VEC direct conversion receivers have
radial
leads; both leads exit from one end of the device body. Each capacitor’s plus (+)
mounting holes are noted both on the circuit board and parts placement diagram.
If the markings on the capacitor body are unclear, the plus (+) lead is always the
longer of the two.
!
!
1. Find the two 470-uF electrolytic capacitors. Install and solder at the
following locations (
observe polarity)
:
!
!
2. C16
470 uF
!
!
3. C17
470 uF
!
!
4. Find the two 10-uF electrolytic capacitors. Install and solder at the
following locations
(observe polarity)
:
!
!
5. C11
10 uF
!
!
6. C15
10 uF
!
!
7. Find the three 1-uF electrolytic capacitors. Install and solder at the
following locations
(observe polarity):
!
!
8. C12
1 uF
!
!
9. C13
1 uF
!
!
10. C14
1 uF
Miscellaneous:
!
!
1. Install the 9-volt battery snap clip. Insert the red
lead at +9V and the
black lead at GND. Solder and trim.