With installations using multiple batteries, the inverter can be operated from one of the
vehicle or vessels’ 12 volt batteries, so there’s always one battery with adequate
charge to start an engine.

Other 

MAXX

SST

3000

features include a high-surge capability (up to 6000

watts), which is required to start heavy loads such as motors and other inductive
devices.

1.3    Warnings, Cautions and Notes:

It is very important that any operator/installer of the inverter read and follow the
installation and operation instructions included in this manual. In particular, close
attention should be paid to the WARNINGS (possibility of serious injury or death),
CAUTIONS (possibility of damage to the inverter and/or other equipment), and
NOTES (included to assist you in achieving the maximum utility and the longest
working life from this advanced-design inverter).

WARNING ABOUT AC OUTPUT

The 

MAXX

SST

3000

is an industrial grade, heavy-duty device that produces

voltages similar to commercial AC power. There are special precautions that must
be taken when you are working with this inverter output. First, Hot and Neutral ter-
minals are both powered with respect to ground. Consider this output as a three-
wire system and NEVER assume that all circuit wires are unpowered because a
front-panel breaker trips. A breaker trips only because the Neutral to Hot load is
greater than 15 amps. The NEUTRAL IS STILL POWERED WHEN A FRONT-PANEL
BREAKER TRIPS. Second, NEVER connect ANY Neutral terminal or wire to ground.
This shorts the output and the inverter will shut down.

The inverter has independent front panel circuit breakers located directly below the
outlet circuits they protect. IF ONLY ONE FRONT-PANEL BREAKER TRIPS,
ALL OTHER OUTPUTS ARE STILL POWERED, INCLUDING THE HIGH OUTPUT
TERMINAL CIRCUITS.

APPLIANCE CAUTIONS

DO NOT plug small appliances into the inverter AC receptacles to directly recharge
their nickel-cadmium batteries. Always use the recharger provided with that appli-
ance.

Do NOT plug in battery chargers for cordless power tools if the charger carries a
warning that dangerous voltages are present at the battery terminals.

WARNING

NO USER-SERVICEABLE COMPONENTS INSIDE.

OPENING UNIT WILL VOID WARRANTY

23

16. Connect an insulated wire (at least 12 AWG) between the grounding screw

on the inverter’s enclosure and a solid electrical ground to minimize possible
electrical noise generation in TVs and radios.

17. Check to ensure that all electrical connections are tight.

18. Ensure that the inverter’s ON/OFF switch is OFF.

19. Insert the fuse into the fuse holder. There may be some sparking.

20. Turn on the inverter and apply a test load to the AC outlets.

21. Observe the LED bar meters and ensure that adequate battery voltage is

present. If you have applied a 600 watt test load, the ammeter should display
50 amps. If it does not:

A.

Check all connections, and tighten any loose connections

B.

Ensure that the battery has an adequate charge

C.

Check the front panel voltmeter to see if adequate voltage is applied
If voltage is low, the cables may be too long or the gauge too light

D.

If steps A through C do not correct the problem, contact Vector Technical
Support Department (954) 584-4446 Ext. 19 for professional direction

22.  Replace the terminal cover and secure with the screws.

5.6. Connection to High Output Terminal Block

External wiring connected to the high output terminal block REQUIRES a
user-supplied dual ganged 30 Amp circuit breaker to protect appliances.

FIGURE 9

shows typical wiring connections using a standard circuit breaker. There

are several types and many manufacturers of circuit breakers available; this
illustration is an example of only one type. A 30 amp Ground Fault Interrupter (GFI)
breaker should be used if the outlets or devices are around water.

Use a Square D type QO230GFICP Plug-On Circuit Breaker And Ground Fault
Interrupter. The physical size of this breaker requires a 70 Ampere load center box
rated at 120/240V single phase ( 3-wire Square D model HOM2-4L70S ). The
breaker has a pig-tail wire that must be connected to the grounding bar inside the
load center box. The Breaker is internally ganged so that both Neutral and Hot
circuits from the inverters’ High Output Terminal Block are switched simultaneously. If
you choose to use a conventional current-only circuit breaker, both Neutral and Hot
must be interrupted. You can use a 50 amp load center because a ganged non-
GFI breaker is physically smaller than a GFI breaker.

Содержание MAXX SST 3000 VEC051

Страница 1: ...d unit of the same or comparable design The repaired or replaced unit will then be warranted under the terms of the remainder of the warranty period The customer is responsible for the shipping charge...

Страница 2: ...THIS POWER INVERTER WARNINGS TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK EXPLOSION OR INJURY Do not connect to AC distribution wiring Remove appliance plug from outlet strip or turn off inverter before...

Страница 3: ...12 VDC battery supply Switch OFF the inverter clean input terminals reconnect input terminals and cable ends reconnect cables Input power source below 10 VDC Recharge or replace power source batterie...

Страница 4: ...inverter shutdown is removed Previously manual reset was required This power inverter also incorporates a new cooling technology that directly benefits our customers The new design more efficiently co...

Страница 5: ...ill automatically shut down until the condition improves FIGURE 2 shows the back panel DC connectors and fan locations Note that the fan only operates when the inverter temperature rises It shuts off...

Страница 6: ...tery configurations with commercial battery chargers or solar battery chargers For most heavy duty applications a multiple battery configuration and the use of deep cycle batteries is a requirement 24...

Страница 7: ...NG NO USER SERVICEABLE COMPONENTS INSIDE OPENING UNIT WILL VOID WARRANTY 23 16 Connect an insulated wire at least 12 AWG between the grounding screw on the inverter s enclosure and a solid electrical...

Страница 8: ...surface that you have selected 2 Mount the fuse holder to its mounting surface using appropriate hardware Ensure that the mounting hardware does not touch any of the fuse holder contacts or fuse conta...

Страница 9: ...battery power you will need Ring terminals to connect two 0000 4 0 cables to the battery bank A single length of not more than ten feet of 0000 4 0 multi stranded flexible insulated cable A 500 amper...

Страница 10: ...e 1 Identify the positive and negative terminals on the 12 volt DC battery and identify the positive and negative terminals on the inverter 2 Remove the plastic terminal cover 3 Using the set of heavy...

Страница 11: ...e ability to operate reactive loads such as those found in inductive motors 19 CAUTIONS This device supplies 110 VAC electrical power directly to the appliances through two standard North American 3 c...

Страница 12: ...llow simultaneous operation of all the AC appliances to be powered with delay characteristics that allow for the momentary high start up current requirements of inductive loads Use the recommended fus...

Страница 13: ...t peak limit the inverter will automatically shut down Once the excessive load is removed the inverter can be restarted and resume normal operation Note If overload shutdown occurs turn OFF the unit a...

Страница 14: ...3 The inverter is in thermal shutdown NOTE It is normal for the alarm to sound when the MAXXSST 3000 is being connected to or disconnected from a 12 VDC power source This does NOT indicate a problem...

Страница 15: ...e indicator will be in the upper red zone Although the inverter has built in protection against overvoltage it may still be damaged if the input voltage exceeds 15 2 volts NOTE Exceeding the recommend...

Страница 16: ...time of 5 minutes but it maintains the temperature of the pot at about 100 watts Typical use of a microwave is only for a few minutes sometimes at low power Some typical exceptions to brief operating...

Отзывы: