background image

  S-19-01-1125-UV101 V1.3 

6. INSTALLATION OF THE UNIT 

 
6.1 Initial set-up 
NOTE: 
Upon receiving the LED Curing Light, check the packaging and parts for any possible damage 
that may have occurred in transit. If damage is apparent, please contact your authorized Vector R & D 
distributor from which the light was purchased. 
 
1.

 

Remove the contents from the shipping package. Be careful not to drop or impact the curing light. 
Choose a flat, level, sturdy surface to place the charging base on. The light is shipped in a “sleep” 
mode, and no timer display. To wake the unit, press the On/Off button. 
 

2.

 

Before using for the first time, the light must be fully charged. For the first charge, this process will 
take about 6 hours. Use only the power supply furnished with the light system. Attempting to use 
another power supply source may cause injury or damage and will void the warranty. 
 

3.

 

Mode button surrounding (charging indicator) illuminates white light during recharging. It will turn 
off automatically after battery is fully charged. 

 
NOTE: On/off button surrounding (power indicator) illuminates white light, indicates the handpiece is 
well connected to power supply. If no white light comes out when connecting power plug to handpeice 
directly or placing handpiece back to charging base, please check the outlet plug is firmly connected or 
not. 

       

       

 

 
 
4.

 

Autoclave the fiber optic light guide prior to first use. Attach the light guide to the hand piece as 
shown in Figure 3. Please refer to Chapter 7 to get more information of optional light guides. 

Figure 3 Insert light guide 

Disconnect light guide 

Содержание LED-P

Страница 1: ...S 19 01 1125 UV101 V1 3 Vector LED Curing Light Vector LED P Instructions For Use VECTOR R D INC 6824 19TH ST 230 UNIVERSITY PLACE WA 98466 USA Website www vectorusa net User Manual...

Страница 2: ...e Environment 6 Installation of the unit p 7 6 1 Initial Setup 6 2 Keypad And Modes 6 3 Timer Selection 6 4 Battery Charging 7 Operation Instruction p 10 8 Operating Errors Trouble shooting p 11 9 Ser...

Страница 3: ...ON Do not look directly into the light emitted from this curing unit It may be harmful to the eyes Exposure must be restricted to the area of the oral cavity in which clinical treatment is intended Do...

Страница 4: ...Check unit for adequate light output before each procedure Failure to verify output may allow inadequate curing 6 In order to avoid electric shock do not introduce any objects into the unit with the...

Страница 5: ...t output at about 1 400 mW cm 3 Seconds to cure most resin based composite in the market It also features Digital timer display multiple mode selection boost fast curing and ramp up soft start Two but...

Страница 6: ...25 minutes Dimensions Diameter 25 30 mm Length with without light guide 240 mm 180 mm Weight with light guide and battery Roughly 155 g 5 3 Charging Base and Handpiece Time to charge empty battery App...

Страница 7: ...take about 6 hours Use only the power supply furnished with the light system Attempting to use another power supply source may cause injury or damage and will void the warranty 3 Mode button surround...

Страница 8: ...all local requirements Always use unit in conjunction with a properly grounded outlet 6 2 Keypad and modes There are 2 buttons on the key pad for the mode timer selection and the on off button Fig 5...

Страница 9: ...tached to the charging base or attach the power supply directly to the handpiece When this is done the POWER INDICATOR On Off button surrounding will illuminate Figure 7 The light may be used with the...

Страница 10: ...the surface being treated Rotate the light guide into the optimal position for polymerization Place the light guide as close to the filling material as possible Avoid directly contacting the filling m...

Страница 11: ...when placing handpiece on the charging base Check the power plug connects to power outlet socket firmly If not sure what happen contact the dealer 6 Battery working time is significantly shortened Ba...

Страница 12: ...l accessories Part Description Contents LM200 Digital Light Radiometer 200 1x Light meter 200 810 Sterilizable fiber optic light guide 10mm diameter 1x 10mm diameter 809 Sterilizable fiber optic light...

Страница 13: ...moved with alcohol a plastic spatula may help in removing the material Do not use any sharp or pointed tools to protect the surface of the light guide from scratching To disinfect place the cleaned li...

Страница 14: ...re shield with a soft cloth and if required a mild cleaning agent Solvents or abrasive cleaners may not be used in any case as they damage the plastic components Make sure that charge connector remain...

Страница 15: ...t by an authorized engineer dealer warranty will expire immediately 13 3 Warranty Exception The warranty stated herein is the sole warranty applicable to Vector R D products Vector R D expressly discl...

Отзывы: