background image

 

TCX2-40863 

P

RODUCT 

D

ATA 

S

HEET

 

 

Doc: 70-00-0174C, 20221118 

© Vector Controls GmbH, Switzerland 

Page 2-10 

Subjects to alteration  

www.vectorcontrols.com 

V

ECTOR

 

Types and Ordering 

Product Name 

Product No.  Loop  UI 

DO 

AO  Functions 

TCX2-40863 

40-110032 

6 Relays 

OP  = With display 
MOD = Communication with Modbus RTU or ASCII 
BAC  = Communication with BACnet MS/TP 
WEM = Com. with Modbus TCP over Wi-Fi with ext. antenna 
WEB = Com. with BACnet IP over Wi-Fi with ext. antenna 
ETM  = Communication with Modbus TCP over Ethernet plug 
ETB  = Communication with BACnet IP over Ethernet plug 

 

TCX2-40863-OP 

40-110036 

TCX2-40863-MOD 

40-110077 

TCX2-40863-OP-MOD 

40-110078 

TCX2-40863-BAC 

40-110079 

TCX2-40863-OP-BAC 

40-110080 

TCX2-40863-WEM 

40-110117 

TCX2-40863-OP-WEM 

40-110133 

TCX2-40863-ETM 

40-110118 

TCX2-40863-OP-ETM 

40-110134 

TCX2-40863-WEB 

40-110126 

TCX2-40863-OP-WEB 

40-110135 

TCX2-40863-ETB 

40-110127 

TCX2-40863-OP-ETB 

40-110136 

UI = Universal inputs, DO = Digital outputs, AO = Analog outputs 

 

Accessories 

Product Name 

Product No.  Description 

Communication 

AEX-MOD 

40-500013 

Modbus RTU or ASCII communication 

AEX-BAC 

40-500044 

BACnet MS/TP communication 

AEC-SMA-01 

40-500146 

Antenna cable kit for external mounting of the Wi-Fi antenna (cable length 1 m) 

AEC-USB-01 

40-500046 

USB to RS-485 converter cable kit used for EasySet tool. Not needed for -WIM or -WIB type  

Input Extension 

AEI-4UI

 

40-500138

 

Accessory for additional 4 universal inputs on a X2 device

 

Mounting 

AMM-1

 

40-510022

 

Mounting kit for panel mounting of the TCX2

 

Memory 

AEC-PM1 

40-500016 

Plug-In memory module for saving and fast copying of parameter sets 

External Operation Terminal 

OPT1-xx

 

40-50xxxx 

A large range of external operation terminals may be found on our website 

www.vectorcontrols.com

All -VC type operation terminals work with this controller. 

OPA2-xx 

40-50xxxx 

 

Safety 

 

DANGER! Safety advice 

This device is for use as an operating controller. It is not a safety device. Where a device failure could endanger 

human life and property, it is the responsibility of the client, installer and system designer to add additional 

safety devices to prevent such a device failure. Ignoring specifications and local regulations may cause equipment 

damage and endangers life and property. Tampering with the device and misapplication will void warranty. 

 

 

 

Содержание 40-110032

Страница 1: ...rol loops o Functions for dehumidifying set point shift and cascade control o Multiple auxiliary functions heat cool auto changeover automatic enable set point compensation o Free heating and cooling...

Страница 2: ...13 Modbus RTU or ASCII communication AEX BAC 40 500044 BACnet MS TP communication AEC SMA 01 40 500146 Antenna cable kit for external mounting of the Wi Fi antenna cable length 1 m AEC USB 01 40 50004...

Страница 3: ...00 VAC to EN 60 730 1 1250 VAC to EN 60 730 1 Electrical connections Connector type Removable connectors wire 0 34 2 5 mm2 AWG 24 12 Remote terminal RS485 in accordance with EIA TIA 485 Shielded twist...

Страница 4: ...4800 9600 19200 38400 Protocol Data bits Parity stop bit RTU 8 data bits ASCII 7 data bits no parity 2 stops even or odd parity 1 stop BACnet BAC Communication standard BACnet MS TP over RS485 BTL tes...

Страница 5: ...sheet document no 70 00 0599 or 70 00 0884 www vectorcontrols com Selection of sensors and actuators Temperature sensors Use Vector Controls NTC sensors to achieve maximum accuracy SDB Tn10 20 duct S...

Страница 6: ...explained in the X2 Operations Manual Reset button TCP IP WEM WEB ETM ETB only The TCP IP configuration setting of the TCX2 can be reset by pressing the reset button with a 1 mm pin through the small...

Страница 7: ...Mounting and installation manual OP MOD BAC TCX2 40863 Install Sheet TCP IP 70 00 0884 Mounting and installation manual WEM WEB ETM ETB X2 Operations Manual button display 70 00 0950 Operations instr...

Страница 8: ...ice management UTC Time synchronisation B DM RD B Device management Reinitialize device B Supported standard BACnet application services ReadProperty ReadPropertyMultiple WriteProperty DeviceCommunica...

Страница 9: ...tions AL 1AL to 8AL 8 Alarm conditions LP 1L to 4L 4 Control loops AO 1A to 3A 3 Analog outputs selectable with jumper mA VDC FAN 1F to 2F 2 Fan or lead lag modules 1 to 3 fan speeds up to 3 switching...

Страница 10: ...1118 Vector Controls GmbH Switzerland Page 10 10 Subjects to alteration www vectorcontrols com VECTOR Smart Sensors and Controls Made Easy Quality Innovation Partnership Vector Controls GmbH Switzerla...

Отзывы: