background image

 

5 After replacing the heating element, test heating element according to the following “5.5.4 test 

the heating element” and install it after confirming it is well.   

6 Tie up the heating element and the handle cord with the strap. 

7 Put the heating element into handle according to the opposite order of disassembling, and the 

heating element must be put into bottom. The bulge of the sensor pin jack should be put into 

handle‟s flute. 

8 Screw down the screw cap at the end of the handle. 

9 Install tip, the sensor pin jack part must be put into the handle‟s flute. 

Note:   

* The joint between wire and pin should be covered with a shrinkable hose. 

* No heating when not installing the tip or else the heating element will be damaged. 

 

4.6.4 Test the heating element 

1 Measure the resistance values between pin 4 and pin1 or pin4 and pin2, between pin5 and pin 

1or pin 2, between pins 3 and pin 1 or pin 2, between pin 3 and pin 4 or pin 5. If they are not 

, the heating element and sensor or vibrator switch are touched. This will damage the PCB. 

2 Measure the resistance value „a‟, „b‟ and „c‟ (refer to the above form) to confirm that the leads 

are not twisted and that the grounding wire is properly connected. 

 

4.7 Replace the fuse

 

1 Turn off the power switch and then pull out the fuse plug in the power plug. 

2 Open the fuse cover board and take out the broken fuse. 

3 replace a new fuse and put back the fuse cover board in place. 

 

 

3.2 Connection 

Page17 

 

Page16 

 

Содержание SD-101

Страница 1: ...SD 101 Intelligent Lead Free Soldering Station Sensor in front Digital Calibration High frequency Rapid recovery of temperature OPERATION MANUAL ...

Страница 2: ...se death of or serious injury to the user CAUTION Misuse may potentially cause injury to the user or physical damage to the objects involved NOTE A Note indicates a procedure or point that is important to the process being described CAUTION When the power is on the tip temperature is very high Mishandling may lead to burns or fire be sure to comply with the following precautions Please use the equ...

Страница 3: ...ron for the other applications except soldering Do not rap the soldering iron against the work bench to shake off residual solder otherwise the iron will be damaged by shocks Do not modify the unit by oneself Replace only with genuine parts Do not wet the soldering station When your hands are wet don t use or disconnect it or pull the supply cord The soldering process will produce smoke so make su...

Страница 4: ...ing 50 250 The time range of the sleeping 0 250 unit minute The time range of the shutting 0 250 unit minute Temperature Stability 2 Without air flow and no load Highest Ambient Temperature 40 Tip to Ground Resistance 2Ω Tip to Ground Potential 2mV Heating Element Electromagnetic heater Handle Power Cord 1 4m Length of Handle Without Cord 180mm Page3 Page2 ...

Страница 5: ...rs by three keys Sleep or turn off automatically at the setting time The up and down limited temperature can be set according to the demands If the temperature exceeds the setting limit value the soldering station sounds alarm Digital calibration and operate conveniently and easy Various types of tips are available and replace tips conveniently The weight is light and the appearance is original ES...

Страница 6: ...h a shrinkable hose No heating when not installing the tip or else the heating element will be damaged 4 6 4 Test the heating element 1 Measure the resistance values between pin 4 and pin1 or pin4 and pin2 between pin5 and pin 1or pin 2 between pins 3 and pin 1 or pin 2 between pin 3 and pin 4 or pin 5 If they are not the heating element and sensor or vibrator switch are touched This will damage t...

Страница 7: ... After displaying about four seconds the station will come into the normal work process and it can set the temperature 3 Input the new password Note the next inputted password must be same with the last inputted password and then the new password will be recorded in the soldering station and change the password successfully Operation as follows 1 Input the new password when inputting the correct i...

Страница 8: ...e is some thing wrong with the heating element H E will be displayed and the power supply to the soldering iron will be cut off 4 6 check and replace the soldering iron When there is something wrong with soldering iron you can check and test it If it is broken replace the broken element 4 6 1 Check the soldering iron 1 Turn the power switch off and disconnect the power plug 2 Disconnect the handle...

Страница 9: ...the modes by pressing and keys The changing series as following Working mode table 3 3 4 Other setting 1 press the or key can change the setting value 2 sleep time setting The station has an auto sleep function When not operating the station during a certain period of time the setting sleep time the power supply will be cut off and the station will come into the sleep state 1 Select the needing mo...

Страница 10: ...displayed refer to the 4 6 Sensor error if there is some malfunction in the sensor or anywhere in the sensor circuit S E will be displayed and the power supply to the soldering iron will be cut off 4 2 Tip s using caution 1 High soldering temperature can degrade the function of the tip and use the tip with the lowest possible soldering temperature The excellent thermal recovery characteristics ens...

Страница 11: ...ing temperature of the soldering station the temperature will fall down to the sleeping temperature Otherwise down to the soldering station s setting temperature Such as If the setting sleeping temperature is 200 and the setting work temperature is 280 in sleeping state the iron s temperature will fall down to 200 If the setting sleeping temperature is 200 and the setting work temperature is 150 i...

Страница 12: ...he temperature still has some departure you can repeat calibration in according with the above steps Note Suggest using the 191 or 192 thermometer to measure the tip s temperature If the soldering station is locked by the password it will not be able to calibrate the tip temperature and you must input the correct password 4 Use care and maintenance 4 1 Select a correct tip 1 Select a tip which max...