11.Temperature Calibration
Whenever the tip is replaced, the temperature of the tip shall be
recalibrated.
Calibrate with thermometer
1) Set a certain temperature value of the soldering station (For
example:350℃).
2) When the temperature is stable, measure the temperature of the tip with
the thermometer, and record the reading value(For example:355℃).
3) Long press the "1" and "3" key at the same time, the soldering station e
nters the temperature calibration mode, when the temperature value displa
yed on the screen turns red, press the "+" or "-" key to change the value to
the actual temperature of the tip , such as 355
℃
measured in step 2,
press "2" (ENTER) key to confirm, if "OK" displayed ,it indicates
calibration is successful, then automatically return to the main interface.