61
©Vecow MTC-6000 User Manual
GETTING TO KNOW YOUR MTC-6000
2.5.10 MCU Spy-bi Wire Interface for Download FW
Header
Pin No.
Interface
J1
1-2
DP (DP2)
2-3
LVDS
The pin assignments of J1 are listed in the following table :
J1
2.6 Ignition Control
2.6.1 Adjust Ignition Control Modes
MTC-6000 series provides ignition power control feature for vehicle applications.
The built-in MCU monitors the ignition signal and turns on/off the system
according to pre-defined on/off delay periods.
MTC-6000 series provides 16 modes of different power on/off delay periods
adjustable via rotary switch. The default rotary switch is set to 0 in ATX/AT
power mode.
SW1