C. The exchanger system takes away the ambient
air. The side with the filter mustn’t be in line with the
aspiration grill, as in the picture 1.6. It can also be in a
different position (see the picture 3.6).
The second solution (picture 3.8) is the best one thanks
to the best sound isolation of the system.
The important thing for the air is to find the shortest and
most linear path, still leaving some space for the filter
maintenance (A).
Top view
Dis. 3-6
Dis. 3-8
Top view
Dis. 3-7
D. The air-conditioner is connected to the electrical box
through cables of 2 m lenght. So there must
be an accessible space (next to the compressor unit
for SPLIT models) to install the electrical box.
E. The thermostat bulb and the aspiration filter must
be mounted on the air-refrigerating gas exchanger.
This side must be accessible for the filter maintenance.
F.- The maximum distance between the control panel
and the electrical box is 3 m both for the thermostat
capillary and for the connection cable.
Dis. 3-9
Dis. 3-10
Dis. 3-11