VECO S.p.A.
Via General Cantore 6/8, 20833 Giussano (MB) Italy
C.F. 06633500159 - P.IVA 00832290969
Phone: +39.0362.35321 | Fax: +39.0362.852995 | E-mail - [email protected] | Web: www.veco.net
3.9- AIR CIRCULATION SYSTEM
3.9.A - ASPIRATION
The ambient air is sucked up through one or more grills of suitable dimensions. The minimum dimensions are 350 X 292
(To canalize the air flow back, call a technical assistance).
3.9.B - AIR CIRCULATION
3.9.C - AIR DUCTS
The efficiency of the system depends on the air volume.
This is why it is important to avoid narrow passages in the air
circulation system, keeping the original diameter dimensions
and using short pipes.
The isolated ducts must not be bent
so that the air can circulate currently.
Cut out the unused length
Top view
Top view
Dis 3-32
Dis 3-31
Dis 3-34
Dis 3-33
Dis 3-35
Dis 3-36
3 COMPONENTS INSTALLATION
3.9.D - FANCOIL EV 4
The fan must be linked by means of a duct to the air distribution
system, that can be constituted of one or more grills and
corresponding plenums.
The main duct diameter must not be inferior to the diameter of
the fan fittings.
The fan can be turned by 90° in case of installatio n in a limited
Height environment.
Dis 3-37
Dis 3-38