background image

01/14

1-10

10

20

21

22

2

1

GB

INSTALLATION INSTRUCTIONS: Viewline 85 mm

TU00-0752-5807102

Technische Änderungen vorbehalten  -  Technical details subject to change

TU00-0752-5807102

Tachometer

To remove the connector, press the latch (

1

) and pull 

the connector out (

2

). 

Important:

 Clean the instrument glass and front frame with water only. Do not use chemical agents.

Accessories / Spare parts 

Bush contacts 0.25 – 0.5 mm²   A2C59510846

Bush housing, 8-pin  

A2C59510847

Bush housing, 14-pin  

A2C59510848

Hand pliers  

Tyco No. 539635-1

Tool for hand pliers  

Tyco No. 539682-2.

Single contacts 0.14 – 0.22 mm²   Tyco No. 1355718-1

Single contacts 0.5 – 0.75 mm²   Tyco No. 963729-1

Strip 0.14 – 0.22 mm²  

Tyco No. 1355717-1

Strip 0.25 – 0.5 mm²  

Tyco No. 928999-1

Strip 0.5 – 0.75 mm²  

Tyco No. 963715-1

Bracket assembly mounting set   A2C59510854

Flush mount fixing bracket  

A2C59510864

Flush mount seal  

A2C53215641

Fastening nut  

A2C53212238

Front ring, flat; black  

A2C53192911

Front ring, flat; white  

A2C53192912

Front ring, flat; chrome  

A2C53192910

Front ring, triangular; black  

A2C53192917

Front ring, triangular; white  

A2C53192920

Front ring, triangular; chrome  

A2C53192918

Front ring, round; black  

A2C53192913

Front ring, round; white  

A2C53192916

Front ring, round; chrome  

A2C53192914

Protective connector cap, 8-pin  A2C53324664

Protective connector cap, 14-pin  A2C53324671

Содержание TU00-0752-5807102

Страница 1: ...nical and electrical airbag area Do not drill holes or ports in load bearing or stabilizing stays or tie bars When working underneath the vehicle secure it according to the specifications from the veh...

Страница 2: ...ion Required mounting depth 65 mm Drill small ports enlarge and complete them if necessary using taper milling tools saber saw keyhole saw or file Debur edges Follow the safety instructions of the too...

Страница 3: ...into the drill hole from the back Adjust the instrument so that the gauge is level and fasten it to the stud bolts on the rear side of the panel using the flush mount fixing bracket A2C59510864 If th...

Страница 4: ...ducing the cable cross sectional area leads to higher current density which can cause the cable cross sectional area in question to heat up When installing electrical cable use the provided cable duct...

Страница 5: ...nut is not tightened with a torque greater than 400 Ncm Make sure the seal lays flat between the panel and the front ring If you would like to omit the fastening nut you may use the part set A2C59510...

Страница 6: ...tting the impulse number 1 Activate T 30 8 pin Pin1 2 Deactivate T 15 8 pin Pin4 3 Press and hold Config key 14 pin Pin 11 Activate T 15 Release Config key Press and hold Config key Set impulse number...

Страница 7: ...y you can switch between 24h and 12h AM PM clock format Press and hold Mode key Press Mode key briefly Press and hold Mode key Set alarm threshold is displayed the first digit flashes Press Mode key b...

Страница 8: ...lay indicator selection 1 Activate T 30 8 pin Pin1 2 Activate T 15 8 pin Pin4 Press Mode key briefly Press Mode key briefly Press Mode key briefly 2 Resetting the day counter 1 Activate T 30 8 pin Pin...

Страница 9: ...s to 0 Press and hold Mode key The next lower digit flashes Press Mode key briefly The flashing digit increases by 1 If the flashing digit is 9 the display returns to 0 Continue until the correct time...

Страница 10: ...gle contacts 0 14 0 22 mm Tyco No 1355718 1 Single contacts 0 5 0 75 mm Tyco No 963729 1 Strip 0 14 0 22 mm Tyco No 1355717 1 Strip 0 25 0 5 mm Tyco No 928999 1 Strip 0 5 0 75 mm Tyco No 963715 1 Brac...

Страница 11: ...r signal Green 6 Lighting Positive Blue Red 7 Warning LED ground Yellow Black 8 Warning LED plus Yellow Red Please read instructions included as some of these pins will not be required Programming Por...