Plug 3: Alarm outputs
Pin No. Designation
Alarm Low
Alarm High
3.1
Alarm 1
OFF
ON : 100°C
3.2
Alarm 2
OFF
ON : 132°C
3.3
Alarm 3
ON : 0.48 Bar OFF
3.4
Alarm 4
ON : 1.90 Bar OFF
3.5
Alarm 5
ON : 10.8V
ON : 16V
3.6
Alarm 6
ON : 10%
OFF
3.7
Alarm 7
ON : 10%V
OFF
3.8
Alarm 8
ON
Alarm output 8 is the collective alarm for alarms 1-7.