49
INSTALLATION
Plug 3 Alarms
Pin No.Colour
Function
Remarks
3.1
brown
Alarm 1
3.2
pink
Alarm 2
3.3
yellow
Alarm 3
3.4
green
Alarm 4
3.5
white
Alarm 5
3.6
grey
Alarm 6
3.7
blue
Alarm 7
3.8
white/brown Alarm 8
3.9
violet
GND
Chassis earth for gauge
3.10
black
GND
Chassis earth for gauge
3.11
red
Term. 30
Output for warning lamps
All alarm outputs are internally limited to 300mA.
Cable lengths / cable cross sections
The permissible cable lengths for the BAIe are:
Cable between gauge and BAIe < 5m
Cable between sensor and BAIe < 5m
The cable cross sections required for the BAIe are:
-
Sensor cable min. 0.5 mm
2
-
Gauge cable min. 0.5 mm
2
-
Power supply min. 0.5 mm
2
-
Data bus min. 0.5 mm
2