52mm Gauges

52mm gauges can only be connected directly to a 110mm Tachometer via an 

EasyLink daisy chain connection. Up to 16 satellite gauges can be connected 

to each tachometer. 

The 52mm gauges are displaying the data distributed by the tachometer. The 
gauges can be used in a VDO or NMEA 2000 network.

Supported NMEA 2000 PGNs

A2C 

Number

Description

Supported PGN

PGN Function

A2C59501925

Engine trim position

127488

Engine Parameters, 

Rapid Update

A2C59501926

Engine oil temperature 52mm 

EasyLink (°C)

127489

Engine Parameters; 

Dynamic

A2C59501927

Engine oil temperature 52mm 

EasyLink (°F)

127489

Engine Parameters; 

Dynamic

A2C59501928 Fresh water level 52mm EasyLink 

127505

Fluid Level

A2C59501929 Black water level 52mm EasyLink 

127505

Fluid Level

A2C59501930

Fuel level 52mm EasyLink

127505

Fluid Level

A2C59501931 Coolant temperature 52mm EasyLink 

(°C)

127489

Engine Parameters; 

Dynamic

A2C59501932 Coolant temperature 52mm EasyLink 

(°F)

127489

Engine Parameters; 

Dynamic

A2C59501933

Exhaust gas temperature 52mm 

EasyLink (°C)

130316

Temperature, Ex-

tended Range

A2C59501934

Exhaust gas temperature 52mm 

EasyLink (°F)

130316

Temperature, Ex-

tended Range

A2C59501935 Engine oil pressure 52mm EasyLink 

(bar)

127489

Engine Parameters, 

Dynamic

A2C59501936 Engine oil pressure 52mm EasyLink 

(psi)

127489

Engine Parameters, 

Dynamic

A2C59501937

Transmission oil pressure 52mm 

EasyLink (bar)

127493

Transmission Pa-

rameters, Dynamic

A2C59501938

Transmission oil pressure 52mm 

EasyLink (psi)

127493

Transmission Pa-

rameters, Dynamic

A2C59501939

Rudder 52mm EasyLink

127245

Rudder

A2C59501940

Battery voltage 52mm EasyLink 

(12V)

127508

Battery Status

Note: 

Engine instance can not be selected

12                                                       

Содержание AcquaLink

Страница 1: ...AcquaLink 110mm Gauges Installation Instructions V1 1 08 16...

Страница 2: ...2...

Страница 3: ...ctions 4 Safety Instructions for Maintenance 6 The VDO 110mm Gauge 7 Components 7 VDO Bus 8 Available versions 8 The NMEA Interface 10 Installation of the VDO 110mm gauge 13 Hardware Specification 16...

Страница 4: ...l be reliable and a great help to you and keep you safe at sea In order to ensure easy and safe handling of your VDO 110mm gauge you should familiarize yourself with all the features and functions Ple...

Страница 5: ...king on the electrical installation on board Please note that with disconnection of the battery all volatile electronic memories lose their input values and must be reprogrammed Explosion hazard Befor...

Страница 6: ...be protected against direct contact through suitable measures Installation of bare metallic wires and contacts is not allowed Take account of the wire cross section A reduction of the wire cross secti...

Страница 7: ...ned with VDO bus cables Please refer to chapter VDO Bus and follow the installation rules and limitations When used in a NMEA 2000 system the gauges can display data present in the NMEA 2000 network P...

Страница 8: ...angle gauge 110 mm A2C59501913 Tachometer 3000 rpm A2C59501914 Tachometer 5000 rpm A2C59501915 Tachometer 7000 rpm VDO Bus The VDO Bus is a proprietary CanBus system based on NMEA 2000 Heart of the VD...

Страница 9: ...DO Bus Limitations The Nav Box provides power to all the 110mm gauges and 4 3 TFTs con nected to the system Due to the power consumption and the resistance of the cables there are limitations of the m...

Страница 10: ...urces the gauge automatically selects the source with the lowest instance number Please follow the general NMEA 2000 installation rules you can find at www nmea org Calculation 12V power supply The vo...

Страница 11: ...01909 Speed over ground 70mph 129026 COG SOG Rapid Update A2C59501910 Speed over ground 35mph 129026 COG SOG Rapid Update A2C59501905 Speed through water 12kn 128259 Speed Water Prefered A2C59501906 S...

Страница 12: ...505 Fluid Level A2C59501930 Fuel level 52mm EasyLink 127505 Fluid Level A2C59501931 Coolant temperature 52mm EasyLink C 127489 Engine Parameters Dynamic A2C59501932 Coolant temperature 52mm EasyLink F...

Страница 13: ...0 mm Drill small ports enlarge and complete them if necessary using taper milling tools saber saws keyhole saws or files Debur edges Follow the safety instructions of the tool manufacturer Before begi...

Страница 14: ...Connect the Bus ca bles and terminators on the rear of the instru ment before fixing the unit to the panel Assemble the unit as shown in the diagram above 14...

Страница 15: ...Fix the gauge by turning the Spinlock in a clockwise direction and locking it hand tight 15...

Страница 16: ...Hardware Specification Connectors Note Connector Y is only on all Tachometers 16...

Страница 17: ...s M12 Connectors Connector Y EasyLink Superseal Connector Only on Tachometers Pin Signal 1 Ignition Kl 15 2 GND Kl 31 3 Battery Kl 30 4 CAN H 5 CAN L 6 GND Kl 31 7 Ignition Kl 15 8 GND Kl 31 Pin Signa...

Страница 18: ...Pin 3 Pin Superseal on Tachometers Operating temperature 20 70 Storage temperature 40 85 Operating voltage range 8 28 VDC Current consumption 300mA Protection Class IP 67 According to IEC 60529 2001...

Страница 19: ...2m A2C39308500 NMEA 2000 Infield Installation Connector Female A2C39310500 NMEA 2000 Infield Installation Connector Male A2C39312700 T Splitter NMEA 2000 A2C39310600 NMEA 2000 Terminator Female A2C393...

Страница 20: ...ich may change as a result of further development of the products This information is merely a technical description of the product It is not meant or intended to be a special guarantee for a particul...

Отзывы: