background image

 

 

Description: 

Alfa(net) 75 RTDF -50/+50°C 

Pages: 

Doc.no: 

150014 

Type: 

Manual 

By: 

BVDB 

Version: 

1.0 

File: 

Do150014 ALFANET 75 RTDF -50+50°C 
V10 EN.docx 

Signed: 

 

Date: 

19-01-2015 

VDH Products BV

 

 

 

 

 

 

Manual               

ALFA(NET) 75 RTDF 

-50/+50°C

 

1

 

Function 

The ALFA(NET) 75 RTDF is a panel mount real-time defrost thermostat with various defrost- and 
fan-control settings. The thermostat has three relays outputs for function cooling, fan and defrost. 

The  room-  and  defrost-temperature  are  being  measured  by  two  SM811  2-wire  temperature 
sensors. 

The ALFANET 75 RTDF is provided with an RS-485 network connection and can be readout or set by 
an PC with the ALFANET program connected thru an ALFANET PC-Interface. 

2

 

Installation 

On  the  connection  diagram  of  the  ALFA(NET)  75  RTDF  is  shown  how  the  sensors,  power  supply, 

relays and optional network are to be connected. After connecting the ALFA(NET) 75 RTDF to the 

power  supply,  a  self-test  function  is  started.  As  this  test  is  finished,  the  measured  room 
temperature of the temperature sensor (control) appears in the display. 

3

 

Control 

The ALFA(NET) 75 RTDF thermostat can be controlled by four pushbutton on the front.  

These keys are;  

SET 

 

- view / change set value and reset alarm. 

∏ 

UP     

- increase set value. 

π 

DOWN  

- decrease set value. 

°C 

 

- hidden push button above SET key and behind °C symbol. 

4

 

Viewing/changing setpoint 

By  pushing  the  SET  key  the  setpoint  appears  in  the  display.  The  decimal  point  of  the  last  display  starts 

blinking, to indicate this readout. A few seconds after releasing the SET key the setpoint disappears and the 
measured temperature is shown again in the display.  
To change the setpoint push the SET key, release the SET key. Now push the SET key again together with the 

UP or DOWN keys to change the setpoint. A few seconds after releasing the keys the measured temperature 
(control) shows again in the display.

 

 

Содержание ALFA 75 RTDF

Страница 1: ...e to be connected After connecting the ALFA NET 75 RTDF to the power supply a self test function is started As this test is finished the measured room temperature of the temperature sensor control app...

Страница 2: ...the DOWN keys simultaneously 8 Fan control The ALFANET 75 RTDF has several parameters for fan control Normally the fan is always active Accept for one of the following parameters to be set to 1 the f...

Страница 3: ...TDF works normally Parameter 33 1 Compressor active at defrost if P24 1 For hot gas defrost systems the compressor needs to be activated while defrosting After defrost the drip off time P27 starts Dur...

Страница 4: ...0 5mm2 only at ALFANET A B 0V Twist A and B Control By four push buttons On the front Front Polycarbonate Dimensions 35 x 77 x 71 5 mm H x W x D Panel cut out 29 x 70 mm H x W Accuracy 0 5 of the rang...

Страница 5: ...0 23 Switch off delay fan 0 99 Minutes 0 24 Defrost mode 0 only fan relay 1 only defrost relay 0 Natural 1 Hotgas Elec 0 25 Switch on delay temperature fan after defrost 50 0 50 0 C 2 0 26 Switch on...

Страница 6: ...ours Off 66 Defrost time 3 Minutes steps 10 Min 0 50 Off Min Off 67 Defrost time 4 Hours 0 23 Off Hours Off 68 Defrost time 4 Minutes steps 10 Min 0 50 Off Min Off 69 Defrost time 5 Hours 0 23 Off Hou...

Страница 7: ...ALFA NET 75 RTDF 50 50 C Doc no 150014 version 1 0 Page 7 of 8 15 Connections Transformer needed at 230Vac power supply...

Страница 8: ...Doc no 150014 version 1 0 Page 8 of 8 16 Dimensions 17 Address VDH Products B V Tel 31 0 50 30 28 900 Productieweg 1 Fax 31 0 50 30 28 980 9301 ZS Roden Email info vdhproducts nl The Netherlands Inte...