9
Remote Control
(Control panel POWER switch must be ON to use remote control.)
BUTTON
ACTION and INDICATION
REMOTE CONTROL
POWER
1.
Press once
. Flame effect turns on High and indicator
light turns on.
2.
Press again
. Power and all functions turn off.
HEATER
1.
Press once
. Small indicator lights up. Fan blows
cool air. 750W heater turns on and blows warm air.
2.
Press again
. Large indicator
lights up. 1500W
heater turns on and blows hot air.
3.
Press again.
Heaters turn off. Fan blows cool air to
allow heater to cool down, then turns off.
FLAME
When the Power is turned on, the flame effect starts at
High.
1.
Press once
. Flame effect changes from High to Low.
2.
Press again
. Flame effect changes from Low to
Medium.
3.
Press again
. Flame effect changes from Medium to
High.
TIMER
1.
Press once
. ½ h light turns on. Timer is set to ½ hour.
2.
Press again
. 1h light turns on. Timer is set to 1 hour.
3.
Press until desired setting is reached
. Timer setting
increases by ½ hour up to 7½ h.
Examples:
3
hours =
2h
+
1h; 7½
hours =
4h
+
2h
+
1h
+
½h
.
4.
Press again.
Timer setting increases by ½ hour until
desired setting is reached, or until timer turns off.
5.
Press again
to restart timer from
½h
.
Temperature Limiting Control
This heater is equipped with a Temperature Limiting Control. Should the heater reach an unsafe
temperature (212
°
F / 100
°
C), the heater will automatically turn OFF. To reset:
1. Unplug the power cord from the outlet.
2. Turn the ON/OFF switch on the CONTROL PANEL to OFF.
3. Wait 5 minutes.
4. Inspect the fireplace to make sure no vents are blocked, or clogged with dust or lint. If they are,
use a vacuum to clean the vent areas.
5. With the POWER switch in the OFF position, plug the power cord back into the outlet.
6. If the problem continues, have your outlet and wiring inspected by a professional.