VDG KVWALL-24B Скачать руководство пользователя страница 9

 

Remote Control 

(Control panel POWER switch must be ON to use remote control.) 

 

BUTTON 

ACTION and INDICATION 

REMOTE CONTROL 

 

POWER 

1. 

Press once

. Flame effect turns on High and indicator 

light turns on. 

2. 

Press again

. Power and all functions turn off.  

 
 

 

 

 

HEATER 

1. 

Press once

. Small indicator    lights up. Fan blows 

cool air. 750W heater turns on and blows warm air. 

2. 

Press again

. Large indicator  

 lights up. 1500W 

heater turns on and blows hot air. 

3. 

Press again.

 Heaters turn off.  Fan blows cool air to 

allow heater to cool down, then turns off. 

 

  

FLAME

 

When the Power is turned on, the flame effect starts at 

High. 

1. 

Press once

. Flame effect changes from High to Low.  

2. 

Press again

. Flame effect changes from Low to 

Medium. 

3. 

Press again

. Flame effect changes from Medium to 

High.  

 

 

TIMER

 

1. 

Press once

. ½ h light turns on.  Timer is set to ½ hour.  

2. 

Press again

. 1h light turns on.  Timer is set to 1 hour.  

3. 

Press until desired setting is reached

. Timer setting 

increases by ½ hour up to 7½ h.  

Examples: 

hours = 

2h

+

1h; 7½

 hours = 

4h

+

2h

+

1h

+

½h

.  

4. 

Press again.

 Timer setting increases by ½ hour until 

desired setting is reached, or until timer turns off. 

5. 

Press again

 to restart timer from 

½h

 

 

Temperature Limiting Control 

This heater is equipped with a Temperature Limiting Control. Should the heater reach an unsafe 

temperature (212

°

F / 100

°

C), the heater will automatically turn OFF. To reset:  

1.  Unplug the power cord from the outlet.  
2.  Turn the ON/OFF switch on the CONTROL PANEL to OFF.  

3.  Wait 5 minutes.  

4.  Inspect the fireplace to make sure no vents are blocked, or clogged with dust or lint. If they are, 

use a vacuum to clean the vent areas. 

5.  With the POWER switch in the OFF position, plug the power cord back into the outlet. 
6.  If the problem continues, have your outlet and wiring inspected by a professional. 

Содержание KVWALL-24B

Страница 1: ...al injury WARNING Read and understand this entire owner s manual including all safety information before plugging in or using this product Failure to do so could result in fire electric shock serious...

Страница 2: ...larly inspect all air vents to make sure they are free from dust lint or other blockage Unplug the unit and clean with a vacuum ONLY DO NOT rinse or get wet WARNING For residential use only NOT for co...

Страница 3: ...a 110 120 Volt 15 Amp grounded circuit NEVER overload the circuit If this heater trips the circuit breaker unplug all other appliances on the same circuit before the next use Avoid plugging other app...

Страница 4: ...e electric drill 1 4 wood drill bit 1 16 wood drill bit and a hammer Parts and Hardware A Fireplace 1 B Wood Screws 3 C Drywall anchors 3 D M4x8 Metal Screws 2 RC Remote Control E Wall Bracket 1 Insta...

Страница 5: ...f only one stud is available the center screw MUST be screwed directly into it and the two outer screws may be screwed into the drywall anchors D Mark the hole locations with a pencil The holes should...

Страница 6: ...or before relocating Failure to do so could result in electric shock fire or personal injury STEP 5 A With the help of a capable adult lift the fireplace and align the two hooks on the back of the fir...

Страница 7: ...ages 2 and 3 Make sure the outlet is in good condition and that the plug is not loose NEVER exceed the maximum amperage for the circuit DO NOT plug other appliances into the same circuit Methods of Op...

Страница 8: ...until desired setting is reached HEATER 1 Press once Small indicator lights up Fan blows cool air 750W heater turns on and blows warm air 2 Press again Large indicator lights up 1500W heater turns on...

Страница 9: ...light turns on Timer is set to hour 2 Press again 1h light turns on Timer is set to 1 hour 3 Press until desired setting is reached Timer setting increases by hour up to 7 h Examples 3 hours 2h 1h 7...

Страница 10: ...cause undesired operation Modifications not approved by the party responsible for compliance could void user s authority to operate the equipment This Class B digital apparatus complies with Canadian...

Страница 11: ...ce the bulb plate and secure it in place with the two screws Note Do not over tighten the screws WARNING Other than replacing the light bulb NO SERVICING of the internal or electrical parts should be...

Страница 12: ...er or any third party whether in contract in tort or on any other basis for any indirect special punitive exemplary consequential or incidental loss cost or damage arising out of or in connection with...

Отзывы: