background image

®

®

1.51

1.61

1.62

1.63

1.64

1.65

1.66 

 

Connect the Protective Earth Terminal    D    on the RF 
Distribution Module to the building Protective Earth System 
if required.

 

Check the resi-linx     IR Modulator is connected to the 
Modulator MOD RF IN input   E   on the RF Distribution 
Module. 

 

From the wall socket, connect a coaxial fly lead to the 

System Input on the IR Target.

 

From the TV output on the IR Target, connect a coaxial fly 

lead to the TV.

 

Steps 1.62 & 1.63 can be repeated for up to 8 TV outputs 
around the premises. NOTE: If an IR Target is not used, 
an in-line DC block should be used.

 

Connect IR emitters (RL-IR700/800) to the outputs on the 
rear of the IR Modulator. Place the emitter head 10mm to 
either side of the IR receiver of the AV source (depending 
on environmental conditions).

 

If required, connect either Single or Double IR Emitter (RL-
IR700/800) to the IR Emitter Port    H    for local control of 
AV source.

1.5 Protective Earth Terminal

1.6 IR Connection

 

 

 

 

No of RF output                                   

      8

No of RF input (2 x Modulator/1 x ANT) 

      3

IR pass back 

 

 

                   Yes

IR emitter port 

                                                  Yes

Output Freq 

                                           37-850 MHz

RF Gain/Loss     - ANT 

                                +2dB

                           - Modulator                                 +3dB
RF Output run distance 

                            60 metres

Isolation (Modulator inputs to ANT)                  -80dB
Power requirement                                  12V DC feed in by remote                                                                                     

 

 

 

 

     power or DC plug pack

Size (mm) 

 

 

       163(l) x 39(h) x 69(d)

WARRANTY

Vcomm Pty Ltd states that the warrant that the customer can rely on is that 

provided by the manufacturer.  In the event of any warranty claim please 

contact us and we will forward it to the manufacturer. The manufacturer will 

then determine the extent of their liability.  This expressly negates, to the 

extent possible by Australian law, any warranty reliance on Vcomm Pty Ltd.

ABN: 99 091 281 524

Vcomm Pty Ltd

www.resi-linx.com

Patented

N15275

by

RL-RF380

Radio Frequency Range

resi-linx

   

 RF Distribution Module

¸

1.71

1.72

 

In the event of FM interference affecting TV channels      

switch    I    to ‘ON’ position.

 

NOTE

 - When ‘ON’ FM radio frequency will be blocked to  

all outputs.

1.7 FM Trap Switch

Отзывы: