VC20XX_HW.pdf – Hardware Documentation VC20XX Smart Cameras
32
8.1.2
Dual voltage, with or without PLC signals, shutdown
Signal
Pin No.
color
connect to
24V IN Cam
2
red/blue
24V backup supply
24V PLC
1
red
24V power supply
24V PLC
9
blue/pink
24V power supply
GND IN com.
3
black
GND power supply
Here, the PLC voltage (24V PLC) is connected directly to the power supply.
If a power failure occurs
or if power is switched off, the camera will detect this signal not being present.
This triggers the
shutdown process:
1. The shutdown process immediately stops the operation of all programs and interrupts (no pictures
will be taken any longer).
2. Then all open buffers will be saved (to multi-media card or flash EPROM).
3. Time and date of the shutdown will be protocolled.
4. The procedure then waits for the backup voltage to disappear or main power to re-establish. If the
latter happens the program might be able to continue where it has stopped. (In this case there
may be some lost images = some parts not checked correctly)
The backup voltage must be able to supply specified voltage for a period of at least 100 msec.
The following
example circuit
may help to understand the principle:
24V PLC
GND
to camera
24V PLC
GND
24V backup
from power supply
capacitor
10000
µ
F
©
1996-2005 Vision Components GmbH Ettlingen, Germany