background image

GPS Menu

DYNAMIC MODE

Press ’■’ and then the ‘◄’ and ‘►’ buttons to select the required dynamics.

HIGH DYNAMICS -

Essential for brake testing and lane changing manoeuvres.

NORMAL -

Select this for standard testing – speed, distance, etc.

LOW DYNAMICS -

Select this for route mapping and similar tests where the level of dynamic

response is not important.

DGPS MODE

Press’■’ and then the ‘◄’ and ‘►’ buttons to select the DGPS settings.

OFF

– No DGPS applied – standard position accuracy 3 m CEP

WAAS

– position accuracy 1.8 m CEP

40CM

– position accuracy 40CM*

20CM

– position accuracy 20CM*

KALMAN FILTER

Press ’■’ and then the ‘◄’ and ‘►’ buttons to set Kalman filter options.

POSITION LEVEL

– Smoothes the positional data

VELOCITY LEVEL

– Smoothes the velocity data

BACK

Press’■’ to return to the GPS menu

*Note: These accuracies are only achievable in conjunction with a DGPS base station

Factory Reset

To perform a factory reset on the unit, if for example the unit is not functioning correctly, press and hold the ’■’
and ‘►’ buttons whilst power is supplied to the VBOX II. The front panel screen will display an '

updating

eeprom

' message screen, notifying you of the process.

11

Содержание II

Страница 1: ...ftware From the main screen press the button to enter the configuration screen Note Entering the configuration screen will cause the VBOX to stop logging to the SD card When in continuous logging mode please ensure that the button is pushed prior to removing the SD card to avoid data loss Once in the configuration screen press the and buttons to highlight the next or previous choice in any menu an...

Страница 2: ...Note The options highlighted in blue are only available on the SL series units 2 ...

Страница 3: ...firm SETUP ANTENNAS Press to enter the antenna configurations menu This menu contains separate sub menus for pitch antenna and roll antenna pairs SMOOTHING Press to edit the smoothing levels of the Lat acc and Long acc channels and also Slip Pitch Roll channels on SL units only OUTPUTS Press configure the digital and analogue outputs EXIT Press to exit the setup menu and cause the settings to be s...

Страница 4: ... the and buttons to choose between the following modes VCI MODE To connect any external CAN modules to the input of the VBOX II RACELOGIC MODULES MODE To connect Racelogic CAN modules to the RLVBOX II input or output LOG OPTIONS Press to enter the Log Options Menu In this menu the Logging Mode and Log rate can be set SERIAL RATE Press and then use the and buttons to select a serial data rate The m...

Страница 5: ...nt But maximum ROLL or PITCH in this mode should be 10 degrees SWAP ANTENNAS Set to ON to allow the primary Antenna A to be mounted ahead of the Secondary Antenna B Default is OFF Then press to confirm SLIP OFFSET Press to enter the Slip offset sub menu Within this sub menu the Slip offset can be calculated and applied or cleared PITCH OFFSET Press to enter the Pitch offset sub menu Within this su...

Страница 6: ...in 0 1 m increments LEVEL Press and then use the and buttons to enable or disable the LEVEL option With the LEVEL set to YES the RTK lock is more resilient But maximum ROLL or PITCH in this mode should be 10 degrees ROLL OFFSET Press to enter the Roll offset sub menu Within this sub menu a Roll offset can be calculated and applied or cleared BACK Press to go back to the Main menu 6 ...

Страница 7: ...hen press to confirm 0 0 5 0 0 1 steps SLIP Press and then use the and buttons to change the amount of smoothing applied to the Slip angle channel Then press to confirm 0 0 5 0 0 1 steps PITCH Press and then use the and buttons to change the amount of smoothing applied to the Pitch angle channel Then press to confirm 0 0 5 0 0 1 steps ROLL Press and then use the and buttons to change the amount of...

Страница 8: ...h steps MAX VALUE Only available when output is set to LAT ACC LONG ACC PITCH SLIP or ROLL Press and then use the and buttons to set the maximum value of that channel Then press to confirm 0 180o 1o steps for Slip 0 90o 1o steps for Pitch 0 90o 1o steps for Roll 0 5 2 g 0 1 g steps for LAT ACC 0 5 2 g 0 1 g steps for LONG ACC MAX FREQUENCY Only available when output is set to LAT ACC LONG ACC PITC...

Страница 9: ...steps LAT ACC 1 to 2 g 0 1g steps LONG ACC VALUE 0V Only available when output is set to SPEED Press and then use the and buttons to set the velocity to represent 0 V Then press to confirm 0 399 km h 1 km h steps VALUE 5V Only available when output is set to LAT ACC LONG ACC PITCH SLIP or ROLL Press and then use the and buttons to set the value to represent 5 V Then press to confirm 2 to 1 g 0 1g ...

Страница 10: ...EXIT Press to exit the setup menu and cause the settings to be saved in EEPROM 10 ...

Страница 11: ...CEP WAAS position accuracy 1 8 m CEP 40CM position accuracy 40CM 20CM position accuracy 20CM KALMAN FILTER Press and then the and buttons to set Kalman filter options POSITION LEVEL Smoothes the positional data VELOCITY LEVEL Smoothes the velocity data BACK Press to return to the GPS menu Note These accuracies are only achievable in conjunction with a DGPS base station Factory Reset To perform a f...