20
2
1
5
3
6
9
4
3
7
200
mm
6
8
E
N
G
8,
CONNECTIONS.
WARNING: The machine connection operations must be carried out
by a specialised and authorised technician.
8.1,
WATER CONNECTION.
Draining
A water drain (1) with siphon must be installed in the vicinity of the machine.
WARNING: The drain siphon must be positioned at least 20cm below
the machine support surface.
•
Remove the drip tray (2) complete with grille.
•
Connect the drain tube (3) provided to the union (4) of the machine and the
other end to the previously prepared
drain siphon (5), checking that the drain
tube runs freely without constrictions or obstructions.
Filling
CAUTION: The machine must absolutely be connected to a water
mains supplying drinking water appropriately softened to a
maximum hardness of 3.5/5 French degrees (60/85 ppm).
Check that the supply pressure does not exceed 2 bar (0.2 MPa). If
the pressure is greater, install a pressure reducer.
•
Connect the filling tube (6) provided to the union (7) of the machine and the
other end to a softener (8).
WARNING: The water supply system should have a shut-off tap (9)
located upstream of the softener to separate the water system from
the machine.
Manuale_ReplicaPistone_Rev0_5lingue_04-2016.indd 20
21/04/16 12:10
Содержание REPLICA PISTONE
Страница 6: ...4 I T A Manuale_ReplicaPistone_Rev0_5lingue_04 2016 indd 4 21 04 16 12 08 ...
Страница 44: ...4 E N G Manuale_ReplicaPistone_Rev0_5lingue_04 2016 indd 4 21 04 16 12 10 ...
Страница 82: ...4 F R A Manuale_ReplicaPistone_Rev0_5lingue_04 2016 indd 4 21 04 16 12 15 ...
Страница 120: ...4 D E U Manuale_ReplicaPistone_Rev0_5lingue_04 2016 indd 4 21 04 16 12 15 ...
Страница 158: ...4 E S P Manuale_ReplicaPistone_Rev0_5lingue_04 2016 indd 4 21 04 16 12 16 ...
Страница 193: ...Retro_ReplicaPistone_Rev0_5lingue_04 2016 indd 3 21 04 16 12 16 ...