Vaxcel Zeta T0619 Скачать руководство пользователя страница 5

Shut-off Delay

● The shut-off delay is the length of time the light will stay at brightness after motion has ceased to be detected.

● You can set the shut-off delay by rotating the delay time knob arrow so it points to the desired time setting  within

“TIME” range. To increase the shut-off delay, turn the knob clockwise. To decrease the shut-off delay, turn the

knob counterclockwise.

1. The sensitivity of the motion sensor will increase as the

environmental temperature gets cooler. You may wish to

make adjustments when the season changes.

For best performance, gently clean the lens with a soft

cloth every 1 or 2 months to assure maximum sensitivity.

2. For best performance, install fixture at least 8 feet above

the ground. At such a height, the fixture will provide a

detection distance of up to 70 feet at 77 degrees

Fahrenheit. (See Fig.8)

3. The sensor detects movement across a detection range

of 240 degrees. (See Fig.9)

4. The sensor will be more sensitive to motion across its

detection path than motion directly towards it. (See Fig.10)

5. To reduce possible nuisances, do not mount the fixture

near a heat source like an air conditioner, vent or furnace

exhaust, or in a direction facing any reflecting object or

other light source.

Page 5 /  6

220207

  5'

8.0'

12.0'

70'

Where you install your fixture is important:

Be sure the light is mounted straight on the wall 

or eave; otherwise, the detection distance may 

be limited. 

Fig.8

Fig. 9

Motion

Least sensitive

Motion

Most sensitive

Sensor

Fig.10

240

°

---The light comes on for no apparent reason 

:

1. Re-aim the motion sensor.

2. Decrease the sensitivity setting.

3. Do not use a dimmer or timer to control the light fixture. Replace the dimmer or timer with a standard on/off wall

---The light flashes on and off:

1. Reposition the lamp heads away from the motion sensor.

2. Reposition the motion sensor.

3. The motion sensor is in “TEST” mode and warm up.

Troubleshooting

1. Make sure the wall switch and circuit breaker are on.

2. Make sure the wiring is correct.

3. Cover the sensor with dark color cloth to verify that the ambient light level is not too high.

Pe

r

formance Notes:

---The light 

does not come on at all:

Customization Options

:

Отзывы: