         7

Vax Careline 

0870 606 1248

dirt container & filter / clearing blockages

The  post  motor  filter  can  be  rinsed  in  warm  water  (max
40ºC).    Allow  to  air  dry  for  at  least  24  hours  before
replacing.

NOTE:  Do  not  use  any  detergents  or  boiling  water  to
wash the filter.   Vax reccommends washing the filter
every 4 weeks).

Replace the post motor filter in the case and re-fit to the
back of the vacuum cleaner.

    7. Clearing Blockages

WARNING:  To  reduce  the  risk  of  electric  shock,
the  power  cord  must  be  disconnected  before

performing maintenance or troubleshooting checks.

Turn the vacuum cleaner off and unplug from the electrical
outlet.

The  flexible  hose  can  be  disconnected  from  the  vacuum
cleaner  by  pushing  in  the  button  on  the  hose  and  pulling
away from the machine. Remove any blockages found then
re-connect the hose securely.

8. Storage

IMPORTANT:  Always  unplug  the  vacuum  cleaner  from
the  electrical  outlet  and  rewind  the  power  cord  as
directed before storing.

NOTE: Always store the vacuum cleaner base down.

!

Vax V-0112AA User Guide:V-112AA User Guide  15/12/2008  09:50  Page 7

Содержание V-112AA

Страница 1: ...sing this cleaner Always fully extend the mains cable before use Retain for future reference Vax careline 0870 6061248 instruction manual Bagless cylinder Vax model number V 112AA Vax V 0112AA User Guide V 112AA User Guide 15 12 2008 09 49 Page 1 ...

Страница 2: ...andle 2 Cord rewind button 3 Variable power dial 4 On off button 5 Dirt container 6 Wheel 7 Carry handle 8 Telescopic tube 9 Combination floor head 10 Dusting brush 11 Crevice tool 12 Upholstery tool 13 Flexible hose 8 13 9 11 10 12 Vax V 0112AA User Guide V 112AA User Guide 15 12 2008 09 50 Page 2 ...

Страница 3: ...k up hot coals cigarette butts matches or any hot smoking or burning objects 13 Do not pick up flammable or combustible materials lighter fluid petrol kerosene etc or use in the presence of explosive liquids or vapours 14 Do not vacuum up harmful or toxic material chlorine bleach ammonia drain cleaner etc 15 Do not vacuum up hard or sharp objects such as glass nails screws coins etc 16 Do not use ...

Страница 4: ...op of the vacuum cleaner and press the button again to turn the vacuum cleaner off Carpet Cleaning For carpet and rug cleaning press the rocker switch on the combination floor head to raise the brushes Hard floor cleaning For hard floor cleaning press the rocker switch on the combination floor head to lower the brushes Cord Rewind To rewind the power cord press the cord rewind button located on th...

Страница 5: ...ays unplug the vacuum cleaner from the electrical outlet before removing the dirt container WARNING Do NOT use the vacuum cleaner without ALL of the filters in place NOTE For best performance replace filters annually Emptying the Dirt Container Press the button located on the top of the dirt container handle to pull out the dirt container Fig 6 1 Position the dirt container over a rubbish bin and ...

Страница 6: ... container turning it clockwise into lock position Replace the dirt container as directed Cleaning the Pre Motor Filter Remove the dirt container as directed Remove the filter as shown Fig 6 6 Rinse the pre motor and foam filter in warm water max 40ºC allow to air dry for at least 24 hours before replacing Fig 6 7 Return the pre motor filter to the dirt container and then to the vacuum cleaner Cle...

Страница 7: ...e the risk of electric shock the power cord must be disconnected before performing maintenance or troubleshooting checks Turn the vacuum cleaner off and unplug from the electrical outlet The flexible hose can be disconnected from the vacuum cleaner by pushing in the button on the hose and pulling away from the machine Remove any blockages found then re connect the hose securely 8 Storage IMPORTANT...

Страница 8: ... loss of suction Cause Dirt container not installed properly Solution Review dirt container replacement Cause Dirt container full or blocked Solution Empty dirt container Cause Clogged filters Solution Remove clean and replace filters PROBLEM Accessories won t pick up Cause Accessories are not attached correctly Solution Refer to section 5 Cause TurboBrush TurboTool is clogged Solution Refer to se...

Страница 9: ...ver 400 approved Vax Service Agents in the UK For the nearest Service Agent please call the Vax Careline www vax co uk 11 Technical Specification Voltage 220 240V 50Hz Wattage 2000W Capacity 1 9 litres approx Filters Central filter wipe clean Pre motor filter washable Post motor filter washable Cord length 4 3m approx Weight 5 6kg Subject to technical change without notice 9 Vax Careline 0870 606 ...

Страница 10: ...www vax co uk 10 This page has been left intentionally blank uk service help technical specification Vax V 0112AA User Guide V 112AA User Guide 15 12 2008 09 50 Page 10 ...

Страница 11: ...11 Vax Careline 0870 606 1248 Vax V 0112AA User Guide V 112AA User Guide 15 12 2008 09 50 Page 11 ...

Страница 12: ...ge Directive EMC 204 108 EC Electromagnetic Compatibility Directive Waste electrical products should not be disposed of with household waste Please recycle where facilities exist Check with your Local Authority or retailer for recycling advice Vax Ltd Kingswood Road Hampton Lovett Droitwich Worcestershire WR9 OQH UK email info vax co uk website www vax co uk Vax V 0112AA User Guide V 112AA User Gu...

Отзывы: