A/V-Source Definition for Auto-TV-Powering
If Auto-TV-Powering is enabled, powering of TVs is based on whether sources are defined as Audio-only or
Audio/Video. The factory setting A/V-Source definition is:
Tuner:
Audio-only (TV off)
CD:
Audio-only (TV off)
Cab/Sat:
A/V (TV on)
VCR-1:
A/V (TV on)
VCR-2:
A/V (TV on)
Laser:
A/V (TV on)
Tape-1:
Audio-only (TV off)
TV/Tape-2:
A/V (TV on)
System-Active-PLC-Power Option
If you wish to have a global “any-zone-on” indication, you may enable System-Active-PLC-Powering, which
sends a unique X-10 command for turning on and off appliance or relay modules. This is a useful method
for powering a multi-zone audio power amplifier. Lamp modules may also be used to turn effect lighting
on and off. This feature is programmed via the computer port. For more information, consult the Vaux
Protocol document.
Example:
This example sets the System-Active HC to F (F16 will be used):
VP F0 67 06 00
This option, if enabled, controls a specific X10 device, and provides a master system-is-active control
function. The House-Code used for this function may be programmed, via the computer port, to a number
(1 to 16) corresponding to the desired House-Code, as follows: 1=A, 2=B, 3=C, ... 16=P, 0=disabled. The
factory-setting is 0, which disables this feature. The Unit-Code is forced to 16 for this feature. For
example, if the system is programmed to used House-Code L for the X-10 System-Active Power option,
then an L16-ON X-10 command is sent when the system first becomes active (a zone turns on from an off
state, and all other zones are currently off), and L16-OFF is sent when the system becomes inactive (a zone
turns off, and all other zones are currently off).
Auto-PLC-Zone-Power Option
For non-IR-controlled zone devices, such as audio power amplifiers, you may also opt to enable Auto-PLC-
Zone-Powering, which sends X-10 commands for turning on and off appliance or relay modules — unique
for each zone. The X-10 modules will turn on or off only as necessary, as the zone turns on or off. Lamp
modules may also be used to turn zone-specific effect lighting on and off. This feature is programmed via
the computer port.
This option, if enabled, sends zone-specific X10 ON/OFF codes. The House-Code used for this function
may be programmed, via the VauxSerial port, to a number (1 to 16) corresponding to the desired House-
Code, as follows: 1=A, 2=B, 3=C, ... 16=P, 0=disabled. The factory-setting is 0, which disables this
feature. The Unit-Code corresponds to the Zone that is turning on or off. For example, if the system is
programmed to used House-Code M for the X-10 Zone Power option, then an M3-ON X-10 command is
sent when Zone 3 turns on, and M3-OFF is sent when the zone turns off.