background image

 

MANUAL OF THERMOSTAT XT110C

 

 

  

 Please read this manual before using 

 

1.AVERTISSEMENT 

 

Warning: disconnect all electrical connections before 
any kind of maintenance. 

 

The instrument must not be opened.

 

 

In case of failure or faulty operation send the instrument 
back to the distributor or to 

 with a 

detailed description of the fault. 

 

2.GENERAL DESCRIPTION  

The XT110C and XT111C are single-stage ON/OFF controllers 
for temperature, humidity and pressure applications with direct 
or inverse action, user-selectable. The analogue input type can 
be set by parameter between the following, according to the 
model: 

-

 

PTC, NTC;  

-

 

PTC, NTC, Pt100, Thermocouple J, K, S;  

4÷20mA, 0÷1V, 0÷10V. 

 

3.FRONT PANEL COMMAND 

 

 

SET

: To display and modify target set point; in programming 

mode it  selects a parameter  or confirm an operation.  

TO SWITCH THE INSTRUMENT ON/OFF

: If the function 

is enabled (par. onF=yES), by pressing the SET key for 
more than 4s the controller is switched OFF. To switch the 
instrument on again press the SET key. 

o

 

UP

: in programming mode it browses the parameter codes or 

increases the displayed value. Hold it pressed for a faster 
change 

n

 

DOWN: 

in programming mode it browses the parameter 

codes or decreases the displayed value. Hold it pressed for 
a faster change 

KEY COMBINATIONS: 
o + n

  To lock & unlock the keyboard

.

 

SET +

 

n

  To enter in programming mode. 

SET + o 

To return to the room temperature display. 

 

3.1 Use of LEDs 

 Each LED function is described in the following table : 

LED  MODE 

FUNCTION 

   ON 

Output relay enabled 

LED1  Flashing  - Programming Phase (flashing with LED2) 
LED2  Flashing  - Programming Phase (flashing with LED1) 
E.S. 

ON 

Energy saving activated by digital input 

  ON 

- ALARM signal 
- In “Pr2” indicates the parameter is also present 
in “Pr1” 

 
 

3.2 To see the set point 

 

Push and release the 

SET 

key to see the Set point 

value 
To come back to the normal display push again the 

SET 

key or 

wait 10s. 

 

3.3 To change the set point 

 

Hold pushed the 

SET 

key for 3s to change the Set 

point value 
The value of the set point will be displayed and the LED1 & 2 
start blinking  
To change the Set value push the 

or 

n

 arrows within 10s. 

To memorise the new set point value push the 

SET

 key again 

or wait 10s. 

 

3.4 To enter the parameters list PR1 

 

  Push  for  3s  the 

SET + n

 keys (LED1 & 2 start 

blinking). 
The controller will display the first parameter present in the Pr1 
menu. 

3.5 How to change a parameter 

- Enter the 

Programming mode 

 

- Select the required parameter. 
- Press the “

SET

” key to display its value. 

- Use “

UP

” or “

DOWN

” to change its value. 

- Press “

SET

” to store the new value and move to the following 

parameter. 
 

TO EXIT

: Press 

SET + UP 

or wait 15s without pressing a key. 

NOTE

: the set value is stored even when the procedure is 

exited by waiting the time-out to expire. 

 

3.6 How to lock the keyboard 

Keep pressed together for more than 3s the the 

and 

n

 keys, 

till the “

POF

” message will be displayed. 

 

3.7 To unlock the keyboard 

Keep pressed together for more than 3s the the 

and 

n

 keys, 

till the “

Pon

” message will be displayed. 

 

4.ALARM SIGNALS 

 

Message  Cause 

Outputs 

“PFo” 
 

Probe broken or 
absence  

Alarm output ON; Output 
according to parameter 
“So1”  

“PFc”  
 

 

Probe short circuited 

Alarm output ON; Output 
according to parameter 
“So1”  

“HA” 
 

Maximum alarm 

Alarm output ON; Other 
outputs unchanged. 

“LA” 
 

Minimum alarm 

Alarm output ON; Other 
outputs unchanged. 

“EAL” 

External alarm 

Output unchanged. 

“bAL” 

Serious external alarm  Output OFF. 

 
 
 

5. PARAMETERS PROGRAMS IN FACTORY  

 

Parameter 40°C 80°C

Set 40 

80 

Hy1 -1 

-1 

LS1 20 

20 

US1 50 

90 

S1C In 

In 

Ac 0 

OPb 25 

25 

 

 

 

 
 
 
 

Содержание REVERSO

Страница 1: ...igerating diagrams page 3 Manual of the thermostat page 4 6 Spare parts page 7 Rue Charles Hermite Z I des Sables BP 59 54110 Dombasle sur Meurthe France tel 33 03 83 45 82 82 fax 33 03 83 45 82 93 e mail commercial vcs vauconsant com export vauconsant com REVERSO ...

Страница 2: ...ing the standard of unit the twist of the self evaporating tray can be situed in the face or in the back of the unit Astainless steel sheet deflector located in the self evaporating tray allow to direct the water vapour The sheet must be located in the middle of the self evaporating tray the same distance in each side The deflector must be located to have the good direction of the inclination like...

Страница 3: ...ter Cd Condensor Sn Level probe D Relief valve St Atmosphere temperature probe Dh Drier Tb Safety thermostat for self evaporating tray E Evaporator Tf Fluorescent tub I 4 positions switch Tr Thermostat XR40 Kb Self evaporating tray relay Ts Safety Thermostat Kd Defrost relay V Well ventilator Lh Halogen lamp Va Variator Q Fuse holder Vc Condensor fan R Heating element ...

Страница 4: ...ed At this point it is only possible the viewing of the set point or the MAX or Min temperature stored and to switch ON and OFF the light the auxilary output and the instrument HOW TO UNLOCK THE KEYBOARD Keep the and the keys pressed together for more than 3 s The POn message will be displayed and the keyboard is unlocked 3 2 Meaning of the LED Each LED function is described in the following table...

Страница 5: ...t message is displayed for about 3s 4 1 EE alarm The instruments are provided with an internal check for the data integrity Alarm EE flashes when a failure in the memory data occurs In such cases the alarm output is enabled 4 2 Alarm recovery Probe alarms P1 probe1 faulty P2 they automatically stop 10s after the probe restarts normal operation Check connections before replacing the probe Temperatu...

Страница 6: ...ital input ON ALARM signal In Pr2 indicates the parameter is also present in Pr1 3 2 To see the set point Push and release the SET key to see the Set point value To come back to the normal display push again the SET key or wait 10s 3 3 To change the set point Hold pushed the SET key for 3s to change the Set point value The value of the set point will be displayed and the LED1 2 start blinking To c...

Страница 7: ...stance with blades length 625 mm power 1250 W X 12 2518 Evaporator length 580 X 12 2520 Evaporator length 900 X 12 2522 Evaporator length 1230 X 12 2524 Evaporator length 1550 X Option crawl heating halogen 06 0622 Halogen lamp power 200W X X X X 06 0620 Aluminium reflector X X X X 06 0625 Protective glass fixing X X X X 06 1520 Variator X X X X Lighting 06 1005 Orange indicator switch X X X X 06 ...

Отзывы: