background image

Item Part #

Description

Wiring Item #

F

AN

A

SSEMBLIES AND

T

HERMOSTATS

A.

12W

Fan Assembly

(1)

Fan Motor, Evaporator

0047000

Standard (120V, 60Hz) 

0439053

Energy Efficient Fan (120V, 60Hz)

0436515

Export (230V, 50 Hz)

0315470

Fan Blade, 
embossing toward motor

B. 0411744

Standard Non-adjustable

(2)

Defrost Thermostat

C. 0353949

Optional Adjustable 

(3)

Refrigeration Thermostat

Item Part #

Description

Wiring Item #

L

AMPS AND

B

ALLASTS

D. 0466234

Ballast, Electronic

2 lamps

(4)

D. 0466235

Ballast, Electronic

3 lamps

(4)

D. 0466236

Ballast, Electronic

4 lamps

(4)

E.

Fluorescent Lamp

(5)

Replace with like fixtures

B

D

D

C

E

A

E

P/N 0453528A

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

Note: Changed items have been underlined.

E4

Data Sheet Set

P/N  0453528A

NSF

®

Certified

October  2005

We reserve the right to change or revise specifications
and product design in connection with any feature of
our products. Such changes do not entitle the buyer to
corresponding changes, improvements, additions or
replacements for equipment previously sold or shipped.

Содержание IMPACT Elite E4

Страница 1: ...D 0466234 Ballast Electronic 2 lamps 4 D 0466235 Ballast Electronic 3 lamps 4 D 0466236 Ballast Electronic 4 lamps 4 E Fluorescent Lamp 5 Replace with like fixtures B D D C E A E P N 0453528A HUSSMANN...

Страница 2: ...52 29 5 8 752 29 5 8 752 29 5 8 752 D RH End of case to RH end of raceway 27 5 8 702 51 5 8 1311 57 1 4 1454 105 1 8 2670 E LH End of case to LH end of raceway 2 1 8 54 2 1 8 54 2 51 2 1 4 57 Waste Ou...

Страница 3: ...re Chart to determine PSIG conversions PHYSICAL DATA Drip Pipe in 1 1 2 Liquid Line in 3 8 Suction Line in 7 8 Estimated Charge lb E4 4 ft 1 1 6 ft 1 9 8 ft 2 3 12 ft 3 3 This is an average for all re...

Страница 4: ...ers NA Minimu Circuit Ampacity With Standard Fans 120V 60Hz 0 90 1 60 1 60 2 30 With Energy Efficient Fans 120V 60 Hz 0 58 0 96 0 96 1 34 With Export Fans 230V 50Hz 0 58 0 96 0 96 1 34 Maximum Over Cu...

Страница 5: ...must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Fan Wiring Offtime Defrost 2 3 Fans 120V NEUTRAL BROWN BAND 120V POWER Fans 1 BROWN BAND Case...

Страница 6: ...ents in 12 foot models only R Red Y Yellow G Green BL Blue B Black W White CIRCLED NUMBERS PARTS LIST ITEM NUMBERS 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B B W BL...

Страница 7: ...is critical to case performance that no product shelf or stop extend beyond the load limit as shown in this illustration This configuration supports the air curtain and provides optimal case performa...