background image

Turbo Air Speed up the Pace of Innovation

Glass Door
Merchandiser
Installation and Operation Manual

CAUTION!

PLEASE KEEP POWER

SWITCH ON BEFORE

OPERATING THIS EQUIPMENT

Please read this manual completely before attempting to install or operate this equipment!

TGM-22RV

www.turboairinc.com

FEATURE CHART

ADVERTISINC 

PANEL

SHELF

BOTTOM 

GRILL

DOOR 

ASSEMBLY

BALLAST

EVAPORATOR 

FAN MOTOR

EVAPORATOR 
FAN BLADE

EVAPORATOR

DRAIN CAP

DRAIN HOSE

SUCTION PIPE 
COVER

COMPRESSOR

DRAIN PAN

HINGE*TOP

FLUORESCENT 

LAMP (32W)

HANDLE

HINGE*UNDER

CONDENSER

CONDENSER 
FAN BLADE

CONDENSER 
FAN MOTOR

FLUORESCENT 

LAMP

ADJUSTABLE 

FOOT

E

D

I

S

T

N

O

R

F

Castors are applied to TGM-22CRV model.
How to install the castor and castor brake : Refer to page 3.
Before operating this unit, please read these instructions completely.

Содержание TGM-22CRV

Страница 1: ...HART ADVERTISINC PANEL SHELF BOTTOM GRILL DOOR ASSEMBLY BALLAST EVAPORATOR FAN MOTOR EVAPORATOR FAN BLADE EVAPORATOR DRAIN CAP DRAIN HOSE SUCTION PIPE COVER COMPRESSOR DRAIN PAN HINGE TOP FLUORESCENT...

Страница 2: ...to make noise Avoid places that are exposed to smoke The discoloring can occur to the refrigerator Set the front of the refrigerator a little bit higher than back side by using adjustable feet to dra...

Страница 3: ...e castor in rear side and the castor brakes in front side by using castor wrench 2 Use the castor shims to level the cabinet if necessary by inserting them to stems of the castors ROTATION CASTOR WITH...

Страница 4: ...cuum cleaner Especially be sure to clean the condensor before reoperating after a long period of non operation Check points after cleaning Check again the refrigerator for safety Do not plug the power...

Страница 5: ...g it Warning Warranty will be voided if the following is found Low voltage to unit Should be 115V 60Hz Power cord should not be more than 7 feet long from plug in connection to compressor Multiple uni...

Страница 6: ...d when the compressor stops This is a sound of REFRIGERANT flowing When compressor stops by temperature control it is not out of order This is necessary so ice will not build up on evaporator The door...

Страница 7: ...7 HOW TO ADJUST A SHELF POSITION AND REPLACE A LAMP...

Страница 8: ...er shipment from manufacturer Compressors determined by Turbo air have been defective within this extended time period will at Turbo air s option be either repaired or replaced with a compressor or co...

Страница 9: ...use accident damage during transit or installation fire flood or an Act of God 4 NO IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THERE ARE NO OTHER WARRANTIES EXPRESS IMPLIE...

Страница 10: ...lubricant The polyol ester lubricant has rapid moisture absorbing qualities 2 Drier replacement is very important and must be changed when a system is opened for servicing A620 copper drier or better...