background image

 SCC P/N    

20-20438 

READ AND SAVE THESE INSTRUCTIONS 

Rev J Date: 5.1.2017 

Specialty / Refrig Self-Svc Island & End Cap CID Case Manual_20-20438.pub 

> REFRIGERATED SELF-SERVICE ISLAND - CID MODELS FSI856R, FSI656R, FSI663R and FSI863R 
> REFRIGERATED SELF-SERVICE PENINSULA END CAP - CID MODEL FSE663R 

888 E. Porter Road · Muskegon, MI  49441  Phone: 231.798.8888  Fax: 231.798.4960  www.structuralconcepts.com

 

INSTALLATION &  

OPERATING MANUAL 

Model FSI663R 

Model FSE663R 

Model FSI656R 

Model FSI863R 

Содержание FSE663R

Страница 1: ...38 pub REFRIGERATED SELF SERVICE ISLAND CID MODELS FSI856R FSI656R FSI663R and FSI863R REFRIGERATED SELF SERVICE PENINSULA END CAP CID MODEL FSE663R 888 E Porter Road Muskegon MI 49441 Phone 231 798 8...

Страница 2: ...DRAIN LAYOUT REFRIGERATION FUNDAMENTALS SELF CONTAINED DRAIN LAYOUT REFRIGERATION FUNDAMENTALS CONDENSATE PACKAGE ACCESS REFRIGERATION FUNDAMENTALS CONDENSATE PACKAGE ILLUSTRATED PARTS BREAKDOWN GENE...

Страница 3: ...sheet contains important warnings to prevent injury or death Please read carefully PRECAUTIONS MAINTENANCE WIRING DIAGRAM INFORMATION See next page for PRECAUTIONS MAINTENANCE and WIRING DIAGRAM info...

Страница 4: ...the following before powering up case Condensate pump must be plugged into receptacle Condensate lines must be connected to condensate pump CAUTION CHECK BOTH CONDENSATE PAN AND OVERFLOW PAN Water on...

Страница 5: ...CE REMOVAL 5 Enlarged View of Shipping Brace For In Line Casters Shown Removed Shipping Brace Attachment Holes Typ Either discard or recycle See illustration below 3 Shipping Brace For In Line Casters...

Страница 6: ...ift truck Move into position KICK PANEL REMOVAL REMOVAL OF CASE FROM PALLET POSITIONING UNIT 6 3 J Bar or Dolly Only No Fork Lift Slide case to edge of pallet With several people in position carefully...

Страница 7: ...may be shimmed to assure that it is level Shims will be provided with such cases Illustration below shows case with frame support rails Note After case has been properly shimmed attach panels No screw...

Страница 8: ...wer levelers until the case is raised off its casters Level case by turning levelers as necessary 3 Raise Levelers Levelers may be raised to allow case to be slid to new location Simply raise levelers...

Страница 9: ...gh Protective Plate Shown After Removal of Knock Outs Caution If ceiling originated lines are used you MUST seal both upper and lower PVC pass throughs at entrance points with expandable foam sealant...

Страница 10: ...ormed by licensed refrigeration contractor 2 Refrigeration Lines at Underside Underside refrigeration lines are standard Refrigeration lines are ALWAYS at rear of case See photograph immediately below...

Страница 11: ...r before providing maintenance and service to unit Assembly disassembly servicing to be performed by licensed refrigeration contractor Condensate pump is located just behind ballast box as shown in il...

Страница 12: ...l Removal To remove panel and access field wiring box lift panel up and off case hooks by grasping firmly and pulling up and outward and separating from retaining magnets 3 Self Contained Cases Only M...

Страница 13: ...l be maintained by following these instructions A Horizontally vented toe kick must be attached to intake side of compressor as shown in item A B Vertically vented toe kick must be attached to the dis...

Страница 14: ...Product 1 Min Product 1 Min Product 1 Min Product Top Shelf RESTRICTED FOOD PRODUCTS SALADS GARDEN CHEF CHICKEN BLT ETC PLACE ON SIDE DECKS ONLY CHEESE STICKS PLACE ON SIDE DECKS OR END CAP DECKS Mid...

Страница 15: ...on rear plenum at upper area of case Digital thermometer is on ALL merchandisers The Check Temperature thermometer is optional See illustrations below Digital Thermometer Optional Check Temperature Th...

Страница 16: ...s check to see that the coil fans are all functioning properly Solenoid location shown on illustration may be on remote cases ONLY View of Evaporator Coil Fans TXV and Drains After Decks and Upper Can...

Страница 17: ...17 MAINTENANCE FUNDAMENTALS SHELF BRACKET ASSEMBLY REMOVAL 1 Shelf Bracket Assembly Removal Shelving is fixed it is not adjustable Screws must be removed to remove shelves See illustrations below...

Страница 18: ...ction of the case LED light fixtures MAY ALSO be located on shelving as shown in photos below 4 LED Light Fixture Removal and Replacement This case is provided with mini LED lights which will rarely r...

Страница 19: ...ly Illustration below shows location of refrigeration lines for remote connection Two 2 drains accessible from top of unit by lifting up decking See POWER UP CHECK EVAPORATOR FAN AREA section in this...

Страница 20: ...Only Illustration below shows location of refrigeration lines for self contained operation Four 4 drains accessible from top of unit by lifting up decking See POWER UP CHECK EVAPORATOR FAN AREA sectio...

Страница 21: ...o case Turn case back on See next page for complete illustrated parts breakdown of condensate package after removal from underside of case Self Contained Units Access to Condensate Package Assembly di...

Страница 22: ...frigeration U Tubes Filter Dryer Electrical Starter Unit Condenser Coil Housing Condenser Coil Fan Fan Housing Motor Overflow Condensate Pan Hot Gas Loop Condensate Pan Wicking Material Optional Sight...

Страница 23: ...spray bottle to spray components Wipe with paper towel Use RINSE spray bottle on components Dry with paper towel Use SANITIZE spray bottle on shelving brackets and molding Let air dry Return product t...

Страница 24: ...c condenser coil air filter from inside of lower panel 3 Use a soft bristled brush or paper towel to wipe Magnetized Condenser Coil Air Filter off excess dust particles and debris from filter DO NOT u...

Страница 25: ...are sharp Handle with care Replace lower panel in reverse order it was removed See sample condenser coil cleaning brushes at right Quarterly Refrigeration Package Compressor Components Self Contained...

Страница 26: ...retainer C Pry downward and away from honeycomb retainer If honeycomb is dirty allow to soak in hot soapy water in back room pot sink Use nylon brush to remove dust A B C D E F debris and stubborn or...

Страница 27: ...connect at the red dot marker at the end of the LED lamp See MAINTENANCE FUNDAMENTALS SHELF BRACKET ASSEMBLY REMOVAL LIGHT FIXTURES section in this manual for more specifics including illustrations If...

Страница 28: ...ounted in brackets Verify that fan blades are securely mounted to fan motor Check that nothing is preventing blade rotation Check that the fan shroud is properly secured Fans Are Not Working Check tha...

Страница 29: ...Control Display Is Flashing See your case s serial label for your model s specified settings See SERIAL LABEL LOCATION INFORMATION LISTED TECH INFO SERVICE for label location etc Case Is Not Holding T...

Страница 30: ...system Check that liquid line filter dryer is not plugged Check that close offs are intact around condensing coil and that air is not recirculating Check that store ambient temperature isn t above max...

Страница 31: ...e is no air recirculation around evaporator coil Check that evaporator coil is not iced up High Suction Pressure Check for refrigerant overcharge Check that compressor reed valves aren t bad Look for...

Страница 32: ...well as regulatory standards to which the case conforms For additional technical information and service see the TECHNICAL SERVICE page in this manual for instructions on contacting Structural Concep...

Страница 33: ...timeout occur normal operational settings prior to modifications being made will resume 3 If the instrument is switched off before pressing the Prg key all modifications to parameters will be lost Se...

Страница 34: ...set reset HACCP alarms reset temp monitoring Summary Table of Alarm and Signals Display Buzzer and Relay Integrated Electronic Microprocessor Controller Read And Save These Instructions Page 2 of 3 Us...

Страница 35: ...tor min F 1 250 d6 Display on hold during defrost C 0 2 dd Dripping time after defrost min F 0 15 d 1 Display of defrost probe 1 C F F 5 Select Celsius C or Fahrenheit F flag C 0 1 35 For Case Specifi...

Страница 36: ...ent by Purchaser Liabilities shall include all costs claims damages judgments and expenses including reasonable attorney fees and costs Remedies of SCC SCC s rights and remedies shall be cumulative an...

Отзывы: