Rev B Date: 6.11.2016 

READ AND SAVE THESE INSTRUCTIONS 

I:\Oper Manuals\Oasis\B4732D_In_Aisle_Ambient_Wall_Unit_20-42840.pub 

M  O  B  I  L  E    S  E  R  I  E  S 

888 E. Porter Road · Muskegon, MI  49441  Phone: 231.798.8888  Fax: 231.798.4960  www.structuralconcepts.com

 

Oasis® 32” Deep Non-Refrigerated Self-Service In-Aisle Grab-N-Go Wall Units

 

SCC P/N 

20-42840 

Model B4732DShown Without  

Optional Roll-Down Security Cover

 

Model B4732 Shown With  

Optional Roll-Down Security Cover

 

INSTALLATION & 

OPERATING MANUAL 

®

 





*Lengths include end panels.

 

Содержание B3632D

Страница 1: ...ter Road Muskegon MI 49441 Phone 231 798 8888 Fax 231 798 4960 www structuralconcepts com Oasis 32 Deep Non Refrigerated Self Service In Aisle Grab N Go Wall Units SCC P N 20 42840 Model B4732DShown W...

Страница 2: ...ER CORD FIELD ACCESS ELECTRICAL BOX BALLASTS LIGHT FIXTURES T8 FLUORESCENTS LIGHT FIXTURES LEDs OPTIONAL ROLL DOWN SECURITY COVER CLEANING SCHEDULE TO BE PERFORMED BY STORE PERSONNEL TROUBLESHOOTING T...

Страница 3: ...warnings to prevent injury or death Please read carefully PRECAUTIONS CORD PLUG MAINTENANCE WIRING DIAGRAM INFORMATION See next page for PRECAUTIONS CORD PLUG MAINTENANCE and WIRING DIAGRAM informati...

Страница 4: ...amaging case See illustration and photos at right 1 Remove Case From Skid Levelers Remove shipping brace that may be securing case to skid Support case to prevent tipping Caution Levelers can be damag...

Страница 5: ...below 2 Turning On Power To Case Plug in power cord Access main power switch by removing front panel lifting up and off not screw removal required Turn on main power switch located on main ballast bo...

Страница 6: ...ld access box is accessible at case rear by removing rear panel Four 4 screws must be removed from panel as shown below to separate from case Light ballasts are located in field access box After provi...

Страница 7: ...e of shelf assembly at the top inside of case and lower front nose of case 7 LIGHT FIXTURES T8 FLUORESCENTS Removal of lamp Rotate lamp 1 4 turn either direction to disengage upper or lower pins conta...

Страница 8: ...ights rarely require change out Contact Structural Concepts Technical Service Department for replacement parts see the Technical Service section of operating manual 8 LIGHT FIXTURES LEDs Replacement o...

Страница 9: ...ll down cover is lowered key may be turned clockwise to lock latch into strike bracket Turn counter clockwise to unlock Keep keys in safe and secure place Latch Lock Keys Views Below Shown Partially D...

Страница 10: ...lic Daily End Panels Front Panels Header Optional Roll Down Security Cover Clean with a warm water and mild soap so lution and soft cloth Monthly Under Case Cleaning Vacuum or use broom to remove all...

Страница 11: ...N power switch is on Check the circuit breaker box for tripped circuits Case Lights Are Not Working Check that light switch is in the on position Check that ALL of the light cords and plugs are proper...

Страница 12: ...l Label For Refrigerated Case Sample Serial Label For Non Refrigerated Case SAMPLE ONLY SAMPLE ONLY SAMPLE ONLY 12 Serial Label Location Information Listed Technical Information Service Serial labels...

Страница 13: ...ent by Purchaser Liabilities shall include all costs claims damages judgments and expenses including reasonable attorney fees and costs Remedies of SCC SCC s rights and remedies shall be cumulative an...