4 ft
6 ft
8 ft
12 ft
General
(A)
Case Length
(without ends or partitions)
48
1
/
8
(1222)
72
1
/
8
(1832)
96
1
/
4
(2445)
144
3
/
8
(3667)
Maximum O/S dimension back to front
(with bumper)
46
1
/
2
(1181)
46
1
/
2
(1181)
46
1
/
2
(1181)
46
1
/
2
(1181)
Back of case to front of front panel
34
1
/
2
(876)
34
1
/
2
(876)
34
1
/
2
(876)
34
1
/
2
(876)
Back of case to O/S edge of front skid rail
29
3
/
8
(746)
29
3
/
8
(746)
29
3
/
8
(746)
29
3
/
8
(746)
Width of skid rail
4
1
/
2
(114)
4
1
/
2
(114)
4
1
/
2
(114)
4
1
/
2
(114)
RH end of case to outside edge of external support
1
3
/
8
(34)
1
3
/
8
(34)
1
3
/
8
(34)
1
3
/
8
(34)
Distance between edges of
external support and center support
NA
28
1
/
2
(724)
40
1
/
2
(1029)
40
1
/
2
(1029)
Distance between edges of center supports
NA
NA
NA
44 (1118)
Stub-up area between front skid rail and front panel
5
3
/
4
(146)
5
3
/
4
(146)
5
3
/
4
(146)
5
3
/
4
(146)
Electrical Service
(Electrical Field Wiring connection point)
(B)
Length of electrical raceway
18
3
/
8
(467)
18
3
/
8
(467)
37 (940)
37 (940)
(C)
RH End of case to center of farthest knockout
36
5
/
8
(930)
60
3
/
4
(1543)
84
3
/
4
(2153)
132
3
/
4
(3372)
Back of case to center of end knockout
29
5
/
8
(752)
29
5
/
8
(752)
29
5
/
8
(752)
29
5
/
8
(752)
(D)
RH End of case to RH end of raceway
27
5
/
8
(702)
51
5
/
8
(1311)
57
1
/
4
(1454)
105
1
/
8
(2670)
(E)
LH End of case to LH end of raceway
2
1
/
8
(54)
2
1
/
8
(54)
2 (51)
2
1
/
4
(57)
Waste Outlet
(F)
RH End of case to the center of waste outlet
24
1
/
4
(616)
24
1
/
4
(616)
24
1
/
2
(622)
72
1
/
4
(1834)
LH End of case to the center of waste outlet
23
7
/
8
(606)
47
7
/
8
(1216)
71
3
/
4
(1822)
72
1
/
8
(1832)
Back O/S of case to center of waste outlet
27
5
/
8
(702)
27
5
/
8
(702)
27
5
/
8
(702)
27
5
/
8
(702)
Water Seal
Edge of water seal to center of waste outlet
4 (102)
4 (102)
4 (102)
4 (102)
Outside diameter of the drip pipe
1
1
/
2
(38)
1
1
/
2
(38)
1
1
/
2
(38)
1
1
/
2
(38)
NOTE: Water seal outlet must clear front skid rail;
water seal rotation in forward direction only due to low base.
Refrigeration Outlet
Back of case to center of refrigeration outlet
30
3
/
4
(781)
30
3
/
4
(781)
30
3
/
4
(781)
30
3
/
4
(781)
RH end of case to center of refrigeration outlet
8
3
/
8
(213)
8
3
/
8
(213)
8
3
/
8
(213)
8
3
/
8
(213)
2 of 7
E4
Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Engineering
Plan Views
Dimensions shown as inches and (mm).
09-2005
34
1
/
2
(876)
8
3
/
8
(213)
Electrical Service
29
5
/
8
(752)
Waste Outlet
Front
C
L
A
C
D
B
F
E
27
5
/
8
(702)
30
3
/
4
(781)
46
1
/
2
(1181)
Water Seal
E4
Dairy/Delicatessen
Precut & Packaged
Produce