P/N 0453532

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

Note: Changed items have been underlined.

E2SPH

Data Sheet Set

P/N  0453532

NSF

®

Certified

October  2005

Item Part #

Description

Wiring Item #

F

AN

A

SSEMBLIES AND

T

HERMOSTATS

A.

12W

Fan Assembly

(1)

0047000

Fan Motor, Evaporator 

0124150

Fan Blade,
embossing toward motor

12W

Energy Efficient Fan Assembly

(1)

0441749

Fan Motor, Evaporator

0124150

Fan Blade,
embossing toward motor

B. 0411744

Standard Non-adjustable

(2)

Defrost Thermostat

C. 0353949

Optional Adjustable 

(3)

Refrigeration Thermostat

Item Part #

Description

Wiring Item #

L

AMPS AND

B

ALLASTS

D. 0466234

Ballast, Electronic

2 lamps

(4)

D. 0466235

Ballast, Electronic

3 lamps

(4)

E.

Fluorescent Lamp

(5)

Replace with like fixtures

O

THER

F.

0464718

Hot Well Assembly

(6)

We reserve the right to change or revise specifications
and product design in connection with any feature of
our products. Such changes do not entitle the buyer to
corresponding changes, improvements, additions or
replacements for equipment previously sold or shipped.

Содержание IMPACT Elite E2SPH

Страница 1: ...embossing toward motor B 0411744 Standard Non adjustable 2 Defrost Thermostat C 0353949 Optional Adjustable 3 Refrigeration Thermostat Item Part Description Wiring Item LAMPS AND BALLASTS D 0466234 Ba...

Страница 2: ...center of waste outlet 24 1 4 616 LH End of case to the center of waste outlet 23 7 8 606 Back O S of case to center of waste outlet 28 1 8 714 Water Seal Edge of water seal to center of waste outlet...

Страница 3: ...ns PHYSICAL DATA Drip Pipe in 1 1 2 Liquid Line in 3 8 Suction Line in 7 8 Estimated Charge lb E2SPH 4 ft 0 9 6 ft 1 8 8 ft 1 9 12 ft 2 9 This is an average for all refrigerant types actual refrigeran...

Страница 4: ...ndard 0 90 120V 50Hz Standard 1 01 230V 60Hz Export 0 53 230V 50Hz Export 0 58 120V 60Hz Energy Efficient 0 58 230V 60Hz Energy Efficient 0 39 Maximum Over Current Protection 120V 20 Maximum Over Curr...

Страница 5: ...0 V Power B W G B BL G W BL Shelf Harness Shelf Light Circuits 4 W R G R Shelf Lighting G R 5 Connector Connector B 4 ft case has 1 Fan 4 ft BL Connector G 120V POWER 120V NEUTRAL Field GROUND Case GR...

Страница 6: ...TRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND BL R 4 5 R 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B 4 ft case has 1 Lamp BL R 4 5 R 4 ft case...

Страница 7: ...at LH or RH Well Marker R Red Y Yellow G Green BL Blue B Black W White 120V POWER 120V NEUTRAL Field GROUND Case GROUND WARNING All components must have mechanical ground and the merchandiser must be...

Страница 8: ...e two locations It is critical to case performance that no product shelf or stop extend beyond the load limit as shown in this illustration This configuration supports the air curtain and provides opt...

Отзывы: