Maintenance 

 

Always  remember  to 

switch  off

  the  appliance  by  opening  the  fuse  holder  before  any 

maintenance operations. 

 

 

Bain-marie well: 

Lift  the  well  from  the  unit.  The 

heating  elements

 

are  accessible  by 

dismantling the ventilation duct inside 
the well by pulling it upwards. 

 
 
 
 
 
 
 

 
 
 
 
 

 

Halogen lighting: 

Halogen  connections  are  located  above 

the halogen support. To access, remove the 2 
mounting screws linking it to the beam. 

 
 

 
 
 
 
 
 
 
 
 
 

 

Electric cabling: 

Electric cabling is fixed behind the built-in control panel.  To access this, remove the 4 screws 

holding the panel. 
 

The installer should check electric connections when commissioning the unit then once a year. 

Any maintenance operation should be done by an electrician. 

 
 
 
 
 
 
 

Well 

Ventilation duct

 

Ventilator 

Heating element

 

Résistance 

Beam

 

Reflector 

Halogen support  

Содержание EXIGENCE A62408

Страница 1: ...757 804 042 EU VAT number FR 52 757 804 042 E EX XI IG GE EN NC CE E P PU UL LS SE ED D A AI IR R B BA AI IN N M MA AR RI IE E W WI IT TH H F FR RE EE E S SP PA AC CE E B BE EL LO OW W A AN ND D H HE...

Страница 2: ...eserved A622xx E633xx rev0 ENG 2 12 2010 2 Manual to be read and kept Contents Introduction 3 Installation Controls 4 Commissioning Use 6 Cleaning Diagnostic 7 Maintenance 8 Electric diagrams 9 Spare...

Страница 3: ...uirements for 120 minutes using GN1 1 150 mm deep gastronome trays The temperature of the food provided should be between 70 C and 80 C To ensure the smooth operation of the unit it is necessary to se...

Страница 4: ...mains in the case of a mobile unit The line should be protected by a differential circuit breaker on the general electricity panel o Installation of a breath shield heating display option 1 Dismantle...

Страница 5: ...ights reserved A622xx E633xx rev0 ENG 2 12 2010 5 Overhang adjustment The unit s overhangs should be positioned as shown below The unit should be level Assembly dismantling of facing Mounting with spa...

Страница 6: ...on at the start of service Use Bain marie well Turn the thermostat button to the right set it to the maximum position This position maintains the temperature of food above 63 C which is the minimum t...

Страница 7: ...it breaker Burnt fuse Check the fuse in the electric cabling Orange light off No heat Faulty supply Check the supply cable Cable disconnected or cut Check and test the electric input on the heating el...

Страница 8: ...y pulling it upwards Halogen lighting Halogen connections are located above the halogen support To access remove the 2 mounting screws linking it to the beam Electric cabling Electric cabling is fixed...

Страница 9: ...se holder Tc Well s thermostat Vtc Ventilator Rc Well s heating element Ts 160 C safety thermostat Features A62213 A62215 Unit reference A62208 E62213TI E622215TI A62219 A62222 Number of heating eleme...

Страница 10: ...lement Ts 160 C safety thermostat Features A62213 A62215 Unit reference A62208 E62213TI E622215TI A62219 A62222 Number of heating elements in the well 1 2 2 2 2 Length of the well s resistance mm 300...

Страница 11: ...oured heating elements with wings 415 long 750 W X X 06 3505 Hot air helical ventilator X X X X X Electric equipment 06 1070 Black PVC button 43 mm X X X X X 06 1188 Safety thermostat X X X X X 06 120...

Страница 12: ...sed by defects or poor maintenance of equipment or damage caused by knocks or improper use Any warranty also excludes incidents caused by fortuitous events or force majeure unidentified causes or caus...

Отзывы: