![VAT 653 - AE Series Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/vat/653-ae-series/653-ae-series_installation-operating-and-maintenance-instructions_855916006.webp)
DESCRIPTION OF PRODUCT
Series 65
6/103
Edition 2019-10-11
980029EB
1.6
Technical data
1.6.1
Control and actuating unit
Description
Power input
1)
(
α
)
+24 VDC (±10%) @ 0.5 V pk-pk max.
[connector: POWER]
[653 . . - . . A . - . . . . / 653 . . - . . H . - . . . . ]
[653 . . - . . C . - . . . . / 653 . . - . . H . - . . . . ]
70 W max. (operation of valve with max. load) without PFO
3)
with optional SPS + 40 W
with optional PFO + 10 W
3)
Sensor power supply
2)
(
β
)
[653 . . - . . A . - . . . . / 653 . . - . . C . - . . . . ]
Input
Output
+24 VDC / 1500 mA max.
±15 VDC (±5%) / 1200 mA max.
[connector: POWER]
[connector: SENSOR]
Sensor power supply
2)
(
β
)
[653 . . - . . G . - . . . . / 653 . . - . . H . - . . . . ]
Input
Output
+ 24 VDC resp. ± 15 VDC
same as input but:
2.0 A max. at ± 15 VDC
1.5 A max. at + 24 VDC
[connector: POWER]
[connector: SENSOR]
Actuator type
Stepper motor with servo control
Ingress Protection
IP30
1)
Internal overcurrent protection by a PTC device.
2)
Refer to chapter «Sensor supply concepts» for details.
3)
PFO = Power Failure Option. Refer to «Behavior in case of power failure» for details.
Calculation of complete power consumption:
P
tot
=
α
+
β
whereas
β
depends on sensor supply concept and sensor power consumption.