OPERATION
Series 642
42/73
Edition 2013-08-22
603685EA
5.1.1
Local operation
Local operation means that the valve is operated via the service port using a computer or the Service Box
2. When using a computer, a service cable and a software from VAT is required.
You can use our Software (freeware) 'Control Performance Analyzer' which can be downloaded from:
http://www.vatvalve.com/customer-service/informations-and-downloads/control-performance-analyzer.
These softwares are beneficial especially for setup, testing and maintenance.
How to start:
Connect service cable between PC and valve controller
, start software and push button ‘LOCAL’ to
enable for operation. Then enter menu Sensor / Setup and do sensor configuration according to your
application to make sure that you get the correct pressure displayed.
‘
'Control Performance
Analyzer' supports:
Valve setup
Sensor setup
Pressure control
Interface setup
Manual control
Sequence ontrol
Numeric and
graphical
monitoring
Data recording
Data analysis
Advanced
diagnostic
When communication to service port is interrupted the valve will change to remote
operation. So when service cable will be disconnected or software will be shut down,
the valve returns automatically to remote operation. This may result in an immediate
movement of the valve depending on remote control.
Refer to «Accessories» for ordering numbers of service cable and Service Box 2.
Содержание 64246-UEHC-0001
Страница 69: ...Series 642 SPARE PARTS 603685EA Edition 2013 08 22 69 73 12 1 Drawing...
Страница 72: ...APPENDIX Series 642 72 73 Edition 2013 08 22 603685EA 13 Appendix No information entered on time...
Страница 73: ...Series 642 603685EA Edition 2013 08 22 73 73 This page left blank intentionally...