VAT 47132-E Series Скачать руководство пользователя страница 2

 

Series 47

 

2/28 

Edition 2018-11-05 

600243EC

 

Imprint 

 
 

 

Manufacturer 

VAT Vakuumventile AG, CH-9469 Haag, Switzerland 

 

 

 

 

 

Website: 
Phone: 
Fax: 
Email: 

www.vatvalve.com 
+41 81 771 61 61 
+41 81 771 48 30 
[email protected] 

 

 

 

 

 

 

 

 

 

 

Publisher 

VAT Vakuumventile AG, CH-9469 Haag, Switzerland 

 

 

 

 

 

 

 

 

 

 

Editor 

VAT Vakuumventile AG, CH-9469 Haag, Switzerland 

 

 

 

 

 

 

 

 

 

 

Print 

VAT Vakuumventile AG, CH-9469 Haag, Switzerland 

 

 

 

 

 

 

 

 

 

 

Copyright 

© VAT Vakuumventile AG 2018 

 

 

 

 

 

No  part  of  these  instructions  may  be  reproduced  in  any  way  (photo-
copies,  microfilms  or  any  other  reproduction  processes)  nor  may  it  be 
manipulated  with  electronic  systems,  duplicated  or  distributed  without 
written permission from VAT. Offenders are liable to pay damages. 

 

 

 

 

 

The  original  VAT  firmware  and  updated  state  of  the  art  versions  of  the 
VAT firmware are intended for use with VAT products. The VAT firmware 
contains a limited, time unlimited user license. The VAT firmware may not 
be  used  for  purposes  other  than  those  intended  nor  is  it  permitted  to 
make  copies  of  the  VAT  firmware.  In  particular,  it  is  strictly  forbidden  to 
give copies of the VAT firmware to other people. 

 

 

 

 

 

The  use  of  trade  names,  brand  names,  trademarks,  etc.  in  these 
Instructions  does  not  entitle  third  parties  to  consider  these  names  to  be 
unprotected  and  to  use  them  freely.  This  is  in  accordance  with  the 
meaning of the laws and acts covering brand names and trademarks. 

 
 

Содержание 47132-E Series

Страница 1: ...r extended pneumatic actuator Series 47 DN 40 250 mm I D 1 10 This manual is valid for the following product ordering numbers With compact actuator With extended actuator 47146 E7 47148 E7 47232 E7 47...

Страница 2: ...duplicated or distributed without written permission from VAT Offenders are liable to pay damages The original VAT firmware and updated state of the art versions of the VAT firmware are intended for u...

Страница 3: ...nto the system 10 4 2 1 Preparation for installation 11 4 2 2 Mounting to the system 12 4 3 Compressed air connection 14 4 4 Electrical connection 15 5 Operation 16 5 1 Normal operation 16 5 2 Operati...

Страница 4: ...umber Order number 1 2 Use of product Use product for clean and dry vacuum applications only Other applications are only allowed with the written permission of VAT 1 3 Related documents Product data s...

Страница 5: ...on Operating Maintenance Instructions are an integral part of a comprehensive documentation belonging to a complete technical system They must be stored together with the other documentation and acces...

Страница 6: ...onnel Inappropriate handling may cause serious injury or property damage Only qualified personnel are allowed to carry out the described work 2 4 Safety labels Label Part No Label size mm Location on...

Страница 7: ...ION 600243EC Edition 2018 11 05 7 28 3 Design and Function 3 1 Design With compact actuator type 47 E7 With extended actuator type 47 E Figure 3 1 1 Actuator 2 Valve body 3 Connecting flange 4 Sealing...

Страница 8: ...he assembled VATRING 7 and counter plate 2 spread apart from the guide plate 3 This effect leaktight closing Opening When the end position is reached the RF contact band 6 which is clamped to the pate...

Страница 9: ...y be useful if products must be returned to VAT Open the plastic bag protecting the valve only at the points where you need access to the eyebolts 1 for fastening the crane hooks see Figure 4 1 on pag...

Страница 10: ...Movable parts Human body parts may get jammed and severely injured Do not connect or supply electrical power and compressed air before the product is completely mounted in the system NOTICE Contaminat...

Страница 11: ...rotective covers from the flanges NOTICE Sensitive product Valve parts may get damaged When removing the protective covers from the flanges be careful to avoid damage to the valve 1 Remove plastic bag...

Страница 12: ...priate flange screws different quantity of screws required depending on valve size 2 Initially mount four screws evenly in crosswise order until the seal touches the sealing surface 3 Afterwards mount...

Страница 13: ...Series 47 INSTALLATION 600243EC Edition 2018 11 05 13 28 Leak detection port Figure 4 4...

Страница 14: ...upply compressed air pressure only after the supply line is properly mounted to the actuator 1 Connect compressed air supply line according the specification on the product data sheet and see Table 4...

Страница 15: ...power NOTICE Wrong voltage Electrical components may get damaged Supply electrical components with the correct voltage 1 Connect position indicator according to product data sheet 2 Connect the conta...

Страница 16: ...tails see product data sheet Make sure that compressed air is supplied at the specified pressure see also chapter 0 Compressed air connection Make sure that the connect voltage is supplied Check volta...

Страница 17: ...g pulse duration min 50 ms Table 5 2 5 2 Operation under increased temperature Maximum allowed temperature see product data sheet NOTICE Inconstant temperatures Performance of the valve may deteriorat...

Страница 18: ...rate DN 40 160 DN 200 250 50 C h 25 C h 50 C h 25 C h Table 5 3 Applied high temperatures and radiation exposure are weakening the sealing materials of the actuator A combination of both will shorten...

Страница 19: ...top Impulse solenoid valve To close the valve Turn the slotted screw 3 coil CLOSE clockwise to its stop As soon as valve is closed turn screw back to its original position To open the valve Turn the s...

Страница 20: ...te seal Please contact VAT www vatvalve com Condition of valve gate Please contact VAT www vatvalve com Operating pressure Adjust operating pressure 0 Compressed air connection Leak at body Condition...

Страница 21: ...1 Maintenance intervals Under clean operating conditions the valve does not require any maintenance during the specified cycles Impacts from the process may require more frequent maintenance When the...

Страница 22: ...airs may only be carried out by the VAT service staff In exceptional cases the customer is allowed to carry out the repairs but only with the prior consent of VAT Please contact one of our service cen...

Страница 23: ...vy weight Physical overstraining Use a crane to lift the product WARNING Hazardous components Human body parts may get jammed and severely injured Before dismounting the product disconnect compressed...

Страница 24: ...owever in reverse order Observe safety instruction of chapter 4 Installation 8 2 Storage NOTICE Wrong storage Inappropriate temperatures and humidity may cause damage to the product Valve must be stor...

Страница 25: ...ysical overstraining Use a crane to lift the product NOTICE Inappropriate packaging Product may get damaged if inappropriate packaging material is used Always use the original packaging material and h...

Страница 26: ...apter 4 2 1 Preparation for installation 2 Pack valve appropriately by using the original packaging material VAT disclaims any liability for damages resulting from inappropriate packaging 9 2 Transpor...

Страница 27: ...Series 47 DISPOSAL 600243EC Edition 2018 11 05 27 28 10 Disposal WARNING Harmful substances Environmental pollution Discard products and parts according to the local regulations...

Страница 28: ...parts may cause damage to the product Use original spare parts from VAT only Parts may only be replaced by the VAT service staff Please contact one of our service centers and specify the fabrication n...

Отзывы: