Series 47
INSTALLATION
600243EC
Edition 2018-11-05
15/28
4.3
Electrical connection
DANGER
Electric shock
Parts being under voltage will result in serious injury or death.
Do not touch parts being under voltage.
NOTICE
Wrong sequence of connections
Valve mechanism may get damaged when electrical power is being
connected before compressed air is connected.
Always connect compressed air before connecting electrical power.
NOTICE
Wrong voltage
Electrical components may get damaged.
Supply electrical components with the correct voltage.
1. Connect position indicator according to product data sheet.
2. Connect the contacts of the solenoid valve connector according to the wiring diagram
on the product data sheet, specification on solenoid coil and; see «Table 4-2».
Execution
Procedure
Without solenoid
valve
47 ... - . E14- ....
47 ... - . E24- ....
47 ... - . E72- ....
n. a.
Standard solenoid
valve
47 ... - . E44- ....
47 ... - . E74- ....
Connect one connector to the magnetic coil.
Impulse solenoid
valve (option)
47 ... - . E44- ....
47 ... - . E74- ....
Connect the relevant connector to the open and close magnetic
coil.
Table 4-2