INSTALLATION
Series 47
10/28
Edition 2018-11-05
600243EC
Use a crane for lifting valve DN100 and higher out of the transport box; see «Figure 4-1».
Weight of standard valves; see chapter «1.5 Technical data».
1 Eyebolts
2 Lifting ropes
A Valve movement
direction
B Support required
to stabilize the
valve
Figure 4-1
4.2
Installation into the system
WARNING
Movable parts
Human body parts may get jammed and severely injured.
Do not connect or supply electrical power and compressed air before the
product is completely mounted in the system.
NOTICE
Contamination
Product may get contaminated.
Always wear cleanroom gloves when handling the product.
NOTICE
Force effect from other components of the system
Valve body may get deformed and/or malfunctions may occur.
– Do not use valve to support other components.
– Make sure that forces from other components do not impair the valve;
use bellows sections, for instance.