Controls 

Breaker Switch 

is used to turn the machine on and off.  In the event of a 

short or electrical failure, the switch will trip into the middle position. If the 
breaker will not reset, or it trips often, contact Vastex tech support or a li-
censed electrician. 

Variable Heat Control 

is used to control the temperature setting.

 

The control 

has positions from LO to HI. The power to the heater(s) is cycled on and off to 
vary the temperature. The higher the number on the controller the longer the 
on cycle and shorter the off cycle time. The “HI” position keeps the power on 
constantly. Check the temp inside the cabinet with a laser temperature gun. 

Red Pilot Light

 (Main Power) is located above the breaker/switch, when 

illuminated, it indicates the switch is in the “on” position, there is power to 
the unit, and the fan(s) will be on. 

Red Pilot Light 

(Heater) is located below the temperature controller, when 

illuminated it indicates the heat is turned on. 

Red Pilot Light 

(Heater) is located above the heat on/off switch, when illumi-

nated it indicates the controller is receiving power. 

Green Pilot Light 

(Control Output), when illuminated, it indicates the control-

ler is calling for heat. 

Temperature Control: 

Microprocessor Based PID Controller. Two digital 

readouts, top digital readout is the “Process Value” (PV), temperature at 
the sensor, bottom readout is the “Set Value” (SV), the temperature you 
set. All values are in Fahrenheit degrees standard but can be changed to 
Celsius. Four buttons along the bottom of the control unit, the two outside 
oval shaped are for setting operating parameters. (Factory set! Do not at-
tempt to alter without consulting a VASTEX factory rep.) The two buttons 
in the middle, the “up arrow” and the “down arrow,” are for adjusting the 
“Set Value”(SV).  A green light (CON) will illuminate when the controller is 
calling for heat (output on).  A red light (ALM) will illuminate when the actu-
al temp is higher than the set value. 

Models:

 VDC-253610 & VDC-513610 

Models:

 VDC-253624, VDC-253610-DHO, & VDC-513610-DHO 

Red Pilot Light 

(Main Power) is located above the breaker/switch, when 

illuminated, it indicates the switch is in the “on” position, there is power to 
the unit, and the fan(s) will be on. 

Breaker Switch 

is used to turn the machine on and off.  In the event of a 

short or electrical failure, the switch will trip into the middle position. If the 
breaker will not reset, or it trips often, contact Vastex tech support or a li-
censed electrician. 

Red Pilot Light 

(Relay Output), when illuminated it indicates the relay con-

tacts are closed and heater should be receiving power. 

VDC-253610 & VDC-513610 

VDC-253624 

VDC-253610 DHO & VDC-513610 DHO 

4

Содержание Dri-Vault VDC-253610

Страница 1: ...rized Representative in Europe Certification Experts BV Nieuwstad 100 1381 CE Weesp The Netherlands Tel 31 0 294 48 33 55 Fax 31 0 294 41 46 87 Vastex E mail assistance Purchasing Product Info sales v...

Страница 2: ...ance Only qualified technicians should be allowed to make repairs on the VASTEX Screen Drying Cabinet Noise and Vibration This noise level produced by this equipment does not exceed 70 dB A VDC 253610...

Страница 3: ...remove fumes and moisture from the work environment Do not exceed 1 elbow 90 deg and or 8 feet of straight duct In the event this must be exceeded a duct fan booster must be added to ensure proper air...

Страница 4: ...ased PID Controller Two digital readouts top digital readout is the Process Value PV temperature at the sensor bottom readout is the Set Value SV the temperature you set All values are in Fahrenheit d...

Страница 5: ...ember while the display point flashes the controller is auto tuning Note If an AT error AtEr occurs the automatic tuning process is aborted due to the system operating in ON OFF control mode PB 0 The...

Страница 6: ...een with a laser temperature gun Make adjustments up or down in order to get between 85 F and 95 F 29 C to 35 C The cabinet can be operated with the heat and blow er or the blower only 4 Once the scre...

Страница 7: ...Chamber contaminated Debris in drying chamber Wipe inside of chamber with lint free cloth then vacuum Pinholes flaws in screen Stability during use transport assembly dismantling testing foreseeable...

Страница 8: ...r licensed trucker shall constitute delivery to Buyer and be determinative of the date and time of shipment and all risk of loss or damage in transit shall be borne by Buyer If the Buyer fails to acce...

Отзывы: