background image

Dri-Vault 

Assembly, Operating, and Maintenance Instructions 

Dri-Vault VDC-253610, VDC-253624, VDC-513610 

            VDC-253610-DHO & VDC513610-DHO 

 Contents 

Page# 



Safety and Machine specs



Assembly instructions



Controls

4-5



Operation, and Maintenance

6



Troubleshooting

7



Warranty

8

Vastex International, Inc. 

7 Emery St

Bethlehem, Pa. 18015 USA 

Phone# 610 625-2702  Fax# 610 625-2775

  

Web Site  www.vastex.com 
E-Mail [email protected]

Authorized Representative in Europe: 

Certification Experts BV 

Nieuwstad 100 1381 CE Weesp,  
T

 

he Netherlands  

Tel : + 31 (0) 294 – 48 33 55  

Fax : + 31 (0) 294 – 41 46 87  

Vastex E-mail assistance 

Purchasing & Product Info: 

[email protected] 

 

Electrical Support: 

[email protected] 

 

Tech Support, Mechanical Setup, and Operation 

[email protected] 

 

Screen Printing Issues & Support: 

[email protected]

  

VDC-513610

VDC-253624

VDC-253610

Serial Number: 

(Please log your machine's serial number and date of purchase for future reference.) 

Date:____/____/______

Electrical Drawing #: 

Rev:______ 

VTX 

Doc. #01-14-011B 

Original Instructions 

Year of manufacture: 

20____

Содержание Dri-Vault VDC-253610

Страница 1: ...rized Representative in Europe Certification Experts BV Nieuwstad 100 1381 CE Weesp The Netherlands Tel 31 0 294 48 33 55 Fax 31 0 294 41 46 87 Vastex E mail assistance Purchasing Product Info sales v...

Страница 2: ...ance Only qualified technicians should be allowed to make repairs on the VASTEX Screen Drying Cabinet Noise and Vibration This noise level produced by this equipment does not exceed 70 dB A VDC 253610...

Страница 3: ...remove fumes and moisture from the work environment Do not exceed 1 elbow 90 deg and or 8 feet of straight duct In the event this must be exceeded a duct fan booster must be added to ensure proper air...

Страница 4: ...ased PID Controller Two digital readouts top digital readout is the Process Value PV temperature at the sensor bottom readout is the Set Value SV the temperature you set All values are in Fahrenheit d...

Страница 5: ...ember while the display point flashes the controller is auto tuning Note If an AT error AtEr occurs the automatic tuning process is aborted due to the system operating in ON OFF control mode PB 0 The...

Страница 6: ...een with a laser temperature gun Make adjustments up or down in order to get between 85 F and 95 F 29 C to 35 C The cabinet can be operated with the heat and blow er or the blower only 4 Once the scre...

Страница 7: ...Chamber contaminated Debris in drying chamber Wipe inside of chamber with lint free cloth then vacuum Pinholes flaws in screen Stability during use transport assembly dismantling testing foreseeable...

Страница 8: ...r licensed trucker shall constitute delivery to Buyer and be determinative of the date and time of shipment and all risk of loss or damage in transit shall be borne by Buyer If the Buyer fails to acce...